首页> 外文期刊>Annals of clinical neurophysiology. >Normal data on axonal excitability in Koreans
【24h】

Normal data on axonal excitability in Koreans

机译:韩国人轴突兴奋性的正常数据

获取原文
           

摘要

Background: Automated nerve excitability testing is used to assess various peripheral neuropathies and motor neuron diseases. Comparing these excitability parameters with normal data provides information regarding the axonal excitability properties and ion biophysics in diseased axons. This study measured and compared normal values of axonal excitability parameters in both the distal motor and sensory axons of normal Koreans. Methods: The axonal excitability properties of 50 distal median motor axons and 30 distal median sensory axons were measured. An automated nerve excitability test was performed using the QTRACW threshold-tracking software (Institute of Neurology, University College London, London, UK) with the TRONDF multiple excitability recording protocol. Each parameter of stimulus–response curves, threshold electrotonus, current–voltage relationship, and recovery cycle was measured and calculated. Results: Our Korean normal data on axonal excitability showed ranges of values and characteristics similar to previous reports from other countries. We also reaffirmed that there exist characteristic differences in excitability properties between motor and sensory axons: compared to motor axons, sensory axons showed an increased strength–duration time constant, more prominent changes in threshold to hyperpolarizing threshold electrotonus (TE) and less prominent changes in threshold to depolarizing TE, and more prominent refractoriness and less prominent subexcitability and superexcitability. Conclusions: We report normal data on axonal excitability in Koreans. These data can be used to compare various pathological conditions in peripheral nerve axons such as peripheral neuropathies and motor neuron disease.
机译:背景:自动神经兴奋性测试用于评估各种周围神经病和运动神经元疾病。将这些兴奋性参数与正常数据进行比较可提供有关患病轴突中轴突兴奋性特性和离子生物物理学的信息。这项研究测量并比较了正常韩国人的远端运动和感觉轴突中轴突兴奋性参数的正常值。方法:测量50个远端正中运动轴突和30个远端正中感觉轴突的轴突兴奋性。使用QTRACW阈值跟踪软件(英国伦敦大学学院神经病学研究所)和TRONDF多重兴奋性记录协议进行了自动神经兴奋性测试。测量并计算了刺激-反应曲线,阈电击,电流-电压关系以及恢复周期的每个参数。结果:我们韩国关于轴突兴奋性的正常数据显示的值和特征范围与其他国家的先前报告相似。我们还重申,运动轴突和感觉轴突之间在兴奋性方面存在特征差异:与运动轴突相比,感觉轴突显示出更高的强度-持续时间常数,超极化阈值电晕(TE)阈值的变化更为明显,而电轴突的变化较小。去极化TE的阈值,以及更高的耐火度和不太突出的亚激发性和超激发性。结论:我们报告了韩国人轴突兴奋性的正常数据。这些数据可用于比较周围神经轴突的各种病理状况,例如周围神经病和运动神经元疾病。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号