...
首页> 外文期刊>Indian Journal of Radiology and Imaging >Comparative accuracy of magnetic resonance morphometry and sonography in assessment of post-cesarean uterine scar
【24h】

Comparative accuracy of magnetic resonance morphometry and sonography in assessment of post-cesarean uterine scar

机译:磁共振形态学和超声检查在评估剖宫产后子宫瘢痕中的比较准确性

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Objective: To compare the diagnostic accuracy of magnetic resonance imaging (MRI) with that of ultrasonography (USG) for the measurement of lower segment cesarean scar during trial of labor after cesarean (TOLAC). Materials and Methods: This was a prospective case-control observational study conducted with a cohort of 30 participants being considered for TOLAC but eventually proceeding to lower segment cesarean section (LSCS) at a university-based teaching institute over a period of 2 years. Measurement of scar thicknesses were done by MRI and USG preoperatively and validated by surgical findings. Comparison of diagnostic accuracy as well as the cut-off values (to differentiate a normal scar from an abnormal scar) was done between the two modalities. Results: Insignificant systematic error between the measurements obtained by the two modalities was noted by a Bland–Altmann analysis. The diagnostic accuracy of USG for differentiating a normal from an abnormal uterine scar was 96.7% while that of MRI was at a slightly lower level of 90%. A strong level of agreement between the two modalities was observed. Conclusion: MRI offers no advantage in diagnostic accuracy for the measurement of LSCS scar thickness during consideration of TOLAC. Advances in Knowledge: Measurement of uterine scar by MRI has a good correlation with that done on USG in the setting of post-cesarean pregnancy. The results hold good both for normal (grades 1 and 2) and abnormal (grades 3) scars. MRI, however, does not offer any added advantage over sonographic scar thickness measurement for the differentiation of a normal (grades 1 and 2) from an abnormal (grade 3) scar.
机译:目的:比较磁共振成像(MRI)和超声检查(USG)在剖宫产后分娩试验(TOLAC)中测量下段剖宫产疤痕的诊断准确性。资料和方法:这是一项前瞻性病例对照观察性研究,由30名参与者组成,他们被考虑接受TOLAC治疗,但最终在2年的时间里在一家大学教学机构进行了下段剖宫产术(LSCS)。术前通过MRI和USG进行疤痕厚度的测量,并通过手术发现进行验证。在两种方法之间比较了诊断准确性和临界值(以区分正常疤痕和异常疤痕)。结果:通过Bland–Altmann分析,注意到两种方法获得的测量值之间的微不足道的系统误差。 USG区分正常和异常子宫瘢痕的诊断准确性为96.7%,而MRI的诊断准确性略低于90%。观察到两种方式之间的高度共识。结论:在考虑TOLAC的过程中,MRI对于LSCS疤痕厚度的测量在诊断准确性方面没有优势。知识进步:在剖宫产后的情况下,MRI对子宫瘢痕的测量与USG的测量有很好的相关性。该结果对于正常(1级和2级)和异常(3级)疤痕均适用。但是,对于区分正常(1级和2级)和异常(3级)疤痕而言,MRI不能提供比超声疤痕厚度测量更高的优势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号