首页> 外文期刊>Indian Journal of Endocrinology and Metabolism >Safety and efficacy of bipolar radiofrequency ablation device in hemostasis during thyroidectomy in comparison with ultrasonic scalpel: A comparative study
【24h】

Safety and efficacy of bipolar radiofrequency ablation device in hemostasis during thyroidectomy in comparison with ultrasonic scalpel: A comparative study

机译:双极射频消融仪与超声刀比较在甲状腺切除术止血中的安全性和有效性:对比研究

获取原文
获取外文期刊封面目录资料

摘要

Aim: Ultrasonic scalpel is one of the recent advances in surgical technology. The main limitation of their use is the cost. However, radiofrequency ablation device is a refined type of electrosurgical cautery that can be used with conventional reusable bipolar cautery forceps. This study aims to compare the efficacy of bipolar radiofrequency ablation device that can be used with conventional reusable bipolar cautery forceps for hemostasis and dissection during thyroidectomy with that of ultrasonic scalpel. Materials and Methods: Sixty patients underwent total thyroidectomy were recruited at Alshiffa General Hospital, Basrah, Iraq from March 2016 to June 2017. The participants were divided into two equal groups: in the first group thyroid dissection was done with ultrasonic scalpel, and in the second group thyroid dissection was done with bipolar radiofrequency ablation device. Outcome and complications of both procedures were analyzed statistically and compared. Results: The bipolar radiofrequency ablation device significantly reduced the mean operative time by (?15.35 min) in comparison to ultrasonic scalpel. The Bipolar Radiofrequency Ablation Device (BRFA) group reported a mean operative time of 50.13 ± 14.16 compared to 65.49 ± 7.78 in the US group with, P value = 0.001. There was no statistically significant difference in the other outcome parameters and the rate of complications reported between the two devices during this study. Conclusion: The bipolar radiofrequency ablation device that can be used with conventional reusable bipolar cautery forceps is a simple, safe, and time-saving adjunct for thyroid surgeries and equally effective as compared to costly instruments like ultrasonic scalpel.Clinical Significance: The bipolar radiofrequency device can be used in thyroid surgery to secure hemostasis, save time, and cost.
机译:目的:超声手术刀是外科技术的最新进展之一。使用它们的主要限制是成本。但是,射频消融设备是一种改良的电外科烧灼类型,可与常规可重复使用的双极电灼钳一起使用。这项研究的目的是比较可与常规可重复使用的双极电灼钳一起使用的双极射频消融器械与甲状腺手术刀在甲状腺切除术中的止血和解剖效果。资料与方法:2016年3月至2017年6月,在伊拉克巴士拉的Alshiffa总医院招募了60例行全甲状腺切除术的患者。参与者分为两组:第一组采用超声解剖刀进行甲状腺解剖,第二组采用超声解剖。第二组甲状腺清扫术采用双极射频消融仪进行。对两种手术的结果和并发症进行统计学分析并进行比较。结果:与超声手术刀相比,双极射频消融设备显着减少了平均手术时间(约15.35分钟)。双极射频消融仪(BRFA)组报告平均手术时间为50.13±14.16,而美国组为65.49±7.78,P值= 0.001。在这项研究中,其他装置的其他结局参数和并发症发生率在统计学上无显着差异。结论:可以与常规可重复使用的双极电灼钳一起使用的双极射频消融装置是甲状腺手术的一种简单,安全且省时的辅助工具,与昂贵的超声手术刀等器械相比同样有效。临床意义:双极射频装置可用于甲状腺手术以确保止血,节省时间和成本。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号