首页> 外文OA文献 >SAFETY AND EFFICACY OF THE BIPOLAR RADIOFREQUENCY ABLATION DEVICE FOR HEMOSTASIS IN THYROIDECTOMY IN COMPARISON WITH THE CONVENTIONAL KNOT-TYING TECHNIQUE
【2h】

SAFETY AND EFFICACY OF THE BIPOLAR RADIOFREQUENCY ABLATION DEVICE FOR HEMOSTASIS IN THYROIDECTOMY IN COMPARISON WITH THE CONVENTIONAL KNOT-TYING TECHNIQUE

机译:与常规结栓技术相比,双极射频消融装置对甲状腺切除术中止血的安全性和有效性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

SAFETY AND EFFICACY OF THE BIPOLAR RADIOFREQUENCY ABLATION DEVICE FOR HEMOSTASIS IN THYROIDECTOMY IN COMPARISON WITH THE CONVENTIONAL KNOT-TYING TECHNIQUE Sadq Ghaleb Kadem*, Sarmad Manea Habash# & Mohammed Khalaf Raheem@ *#@MB,ChB, FICMS, Department of Surgery, Al-Shiffa General Hospital, Basrah, IRAQ Abstract The conventional method of hemostasis by using knot-tying technique is safe and effective in thyroid surgery but it is time consuming. A new energy devices like ultrasonic scalpel and advanced bipolar electrosurgical cautery have been proven to be safe and effective in shortening the length of thyroid surgery but the high cost of these advanced generators that designed to work only with an expensive disposable hand pieces, make its use difficult to justify in some hospitals. Radiofrequency ablation device is a refined type of electrosurgical cautery that utilizes a wave of electrons at a frequency between 2 and 4MHz to seal and divide the targeted tissue and the ablation property of this device act as an extra vessel sealing effect, it can be used with conventional reusable bipolar electrosurgical cautery hand pieces. The aim is to evaluate the safety and efficacy of a simple bipolar radiofrequency ablation device for hemostasis in thyroidectomy in comparison with the conventional knot-tying technique. This study was conducted in Alshiffa General Hospital following the approval of the local ethical committee. Fifty patients with different thyroid gland pathologies underwent total thyroidectomy in which hemostasis was achieved mainly with bipolar radiofrequency ablation device. The results of this group were compared with results of conventional knot-tying technique by the same surgical team at an earlier period. This study showed that bipolar radiofrequency ablation device significantly reduced; mean operative time, amount of foreign suture material, significant reduction in the mean volume of postoperative drainage, early patient discharge from hospital, and less complications. In conclusion, the use of the bipolar radiofrequency ablation device with conventional reusable bipolar cautery forceps for hemostasis in thyroidectomy is a safe, simple technique and effective in reducing the operative time in comparison with the conventional knot-tying technique.
机译:与甲状腺切除术中止血骨止血的双极射频消融装置的安全性和有效性与传统的结栓技术萨德克·瓦格尔·卡德姆*,SARMAD曼厄姆哈夫斯#&穆罕默德·哈拉夫·拉赫夫@ *#@ MB,CHB,FICMS,外科,al - Shiffa General医院,Basrah,伊拉克摘要通过使用结栓技术,在甲状手术中是安全有效的止血方法,但它是耗时的。已经证明了一种新的能量装置,如超声波手术刀和先进的双极电外科烧灼,缩短了缩短甲状手术的长度,但这些先进发电机的高成本仅使用昂贵的一次性手工件,使其使用在一些医院难以证明。射频消融装置是一种精制类型的电外科烧灼类型,其在2至4MHz之间的频率下采用电子的光,以密封并分开该器件的消融性能作为额外的船舶密封效果,可以使用常规可重复使用双极电外科烧灼手工件。目的是评估简单的双极射频消融装置的安全性和功效,与传统的结绑扎技术相比,甲状腺切除术中止血的安全性和功效。本研究在批准当地道德委员会后在Alshiffa综合医院进行。 50例不同的甲状腺腺体病理患者进行了总甲状腺切除术,主要用双极射频消融装置实现了止血。将该组的结果与在早期的同一外科手术团队的常规结技术的结果进行比较。这项研究表明,双极射频消融装置显着降低;平均手术时间,外来缝合材料的量,术后引流的平均体积显着降低,早期患者从医院出院,并并发症较少。总之,使用与甲状腺切除术中止血的常规可重复使用的双极性灼热钳的双极射频消融装置是一种安全,简单的技术,并且与传统的结绑技术相比,减少操作时间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号