...
首页> 外文期刊>Imaging Science in Dentistry >Diagnostic accuracy of cone-beam computed tomography scans with high- and low-resolution modes for the detection of root perforations
【24h】

Diagnostic accuracy of cone-beam computed tomography scans with high- and low-resolution modes for the detection of root perforations

机译:高分辨率和低分辨率模式的锥束计算机断层扫描的诊断准确性,用于检测牙根穿孔

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Purpose This study compared the diagnostic accuracy of cone-beam computed tomography (CBCT) scans obtained with 2 CBCT systems with high- and low-resolution modes for the detection of root perforations in endodontically treated mandibular molars. Materials and Methods The root canals of 72 mandibular molars were cleaned and shaped. Perforations measuring 0.2, 0.3, and 0.4 mm in diameter were created at the furcation area of 48 roots, simulating strip perforations, or on the external surfaces of 48 roots, simulating root perforations. Forty-eight roots remained intact (control group). The roots were filled using gutta-percha (Gapadent, Tianjin, China) and AH26 sealer (Dentsply Maillefer, Ballaigues, Switzerland). The CBCT scans were obtained using the NewTom 3G (QR srl, Verona, Italy) and Cranex 3D (Soredex, Helsinki, Finland) CBCT systems in high- and low-resolution modes, and were evaluated by 2 observers. The chi-square test was used to assess the nominal variables. Results In strip perforations, the accuracies of low- and high-resolution modes were 75% and 83% for NewTom 3G and 67% and 69% for Cranex 3D. In root perforations, the accuracies of low- and high-resolution modes were 79% and 83% for NewTom 3G and was 56% and 73% for Cranex 3D. Conclusion The accuracy of the 2 CBCT systems was different for the detection of strip and root perforations. The Cranex 3D had non-significantly higher accuracy than the NewTom 3G. In both scanners, the high-resolution mode yielded significantly higher accuracy than the low-resolution mode. The diagnostic accuracy of CBCT scans was not affected by the perforation diameter.
机译:目的这项研究比较了使用2种具有高分辨率和低分辨率模式的CBCT系统获得的锥束计算机断层扫描(CBCT)扫描的诊断准确性,以检测经牙髓治疗的下颌磨牙的牙根穿孔。材料与方法清洁和成形72个下颌磨牙的根管。在48个根的分叉区域创建直径为0.2、0.3和0.4 mm的孔,模拟条状穿孔,或在48个根的外表面模拟模拟根孔。四十八根保持完整(对照组)。用牙胶(Gapadent,中国天津)和AH26密封剂(Dentsply Maillefer,瑞士Ballaigues)填充根。 CBCT扫描是使用NewTom 3G(QR srl,意大利维罗纳)和Cranex 3D(Soredex,赫尔辛基,芬兰)CBCT系统在高分辨率和低分辨率模式下获得的,并由2位观察者进行了评估。卡方检验用于评估名义变量。结果在带状穿孔中,NewTom 3G的低分辨率和高分辨率模式的准确度分别为75%和83%,Cranex 3D的精确度为67%和69%。在根部穿孔中,NewTom 3G的低分辨率和高分辨率模式的准确度分别为79%和83%,Cranex 3D的精确度为56%和73%。结论2个CBCT系统在检测条带和根部穿孔方面的准确性有所不同。 Cranex 3D的精度比NewTom 3G高得多。在两种扫描仪中,高分辨率模式都比低分辨率模式产生了更高的精度。 CBCT扫描的诊断准确性不受穿孔直径的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号