One of the serious problems in the conventional transmission system, which uses the Neutral and Live (N-L) conductors, for the Narrow-Band Power-Line Communications (NB-PLC) is the low Signal to Noise Ratio (SNR) property. To improve it, a new signal transmission system, which uses the Protective Earth (N-PE) conductor instead of L, has been proposed in this letter. The proposed method is called N-PE system. The results show that the receiving SNR, the channel capacity, and the Packet Reception success Rate (PRR) values of the N-PE system were superior to those of the N-L system, except for the noise property.
机译:对于窄带电力线通信(NB-PLC),使用中性和带电(N-L)导体的常规传输系统中的严重问题之一是信噪比(SNR)低。为了改进它,在本信函中提出了一种新的信号传输系统,该系统使用保护性接地(N-PE)导体代替L。所提出的方法称为N-PE系统。结果表明,除了噪声特性外,N-PE系统的接收SNR,信道容量和数据包接收成功率(PRR)值均优于N-L系统。