首页> 外文期刊>Asian spine journal. >Quantitative Anatomy of C7 Vertebra in Southern Chinese for Insertion of Lateral Mass Screws and Pedicle Screws
【24h】

Quantitative Anatomy of C7 Vertebra in Southern Chinese for Insertion of Lateral Mass Screws and Pedicle Screws

机译:中国南方C7椎骨侧向螺钉和椎弓根螺钉插入的定量解剖

获取原文
           

摘要

Study Design Retrospective study. Purpose To analyze the quantitative anatomy of C7 vertebra for insertion of lateral mass screws and pedicle screws in Southern Chinese patients. Overview of Literature C7 lateral mass is smaller when compared to other subaxial cervical levels, which limits the length of lateral mass screws that can be used. Some studies have suggested pedicle screws for better fixation. But, this option is limited by the narrow pedicle width. Methods We have obtained computed tomography (CT) cervical spine data in 0.625 mm slices from our radiology department. The patients were adults. CTs were from May to August, 2015. The lateral mass screw length was measured using Margerl's technique and pedicle width and pedicle screw trajectory were determined in three-dimensional reformated images. Results CT scans of cervical spines of 94 patients were obtained and 188 lateral masses and pedicles of C7 vertebrae were measured. The mean lateral mass screw length was 13.2 mm (standard deviation [SD] 1.6 mm), mean outer pedicle width was 5.9 mm (SD 1.0 mm) and mean pedicle screw trajectory was 29.4 degrees (SD 3.6 degrees). Most (91.0%) of the pedicles had an outer diameter ≥4.5 mm. Conclusions The mean lateral mass screw length was longer when compared with other similar studies, while the mean outer pedicle width was narrower. Nearly 10% of the pedicles were unable to accommodate 3.5 mm screws. These findings favor the use of lateral mass screws to provide a safe and stable fixation for C7 vertebrae in Southern Chinese patients, while the final choice of fixation method should only be confirmed after careful preoperative planning with CT scan.
机译:研究设计回顾性研究。目的分析中国南方患者插入侧块螺钉和椎弓根螺钉的C7椎骨的定量解剖结构。文献概述与其他亚轴颈椎水平相比,C7侧向质量较小,这限制了可使用的侧向质量螺钉的长度。一些研究表明椎弓根螺钉可以更好地固定。但是,这种选择受到狭窄的椎弓根宽度的限制。方法我们从放射科获得了0.625 mm切片的计算机断层扫描(CT)颈椎数据。患者是成年人。 CT扫描时间为2015年5月至2015年8月。使用Margerl的技术测量侧质量螺钉长度,并在三维重建图像中确定椎弓根宽度和椎弓根螺钉轨迹。结果对94例颈椎进行了CT扫描,测量了C7椎骨的188个侧块和蒂。平均侧向质量螺钉长度为13.2毫米(标准偏差[SD] 1.6毫米),平均椎弓根外侧宽度为5.9毫米(SD 1.0毫米),平均椎弓根螺钉轨迹为29.4度(SD 3.6度)。大部分(91.0%)椎弓根的外径≥4.5mm。结论与其他类似研究相比,平均侧质量螺钉长度更长,而平均外侧椎弓根宽度更窄。接近10%的椎弓根不能容纳3.5毫米的螺钉。这些发现有利于在中国南方患者中使用侧向大头螺钉来为C7椎骨提供安全稳定的固定,而最终的固定方法选择应在仔细的术前CT扫描计划后确定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号