首页> 外文期刊>Annals of laboratory medicine. >Interlaboratory Comparison of the Results of Lifecodes LSA Class I and Class II Single Antigen Kits for Human Leukocyte Antigen Antibody Detection
【24h】

Interlaboratory Comparison of the Results of Lifecodes LSA Class I and Class II Single Antigen Kits for Human Leukocyte Antigen Antibody Detection

机译:用于人白细胞抗原抗体检测的Lifecode LSA I类和II类单一抗原试剂盒结果的实验​​室间比较

获取原文
           

摘要

Background: Although single antigen bead assays (SAB) are approved qualitative tests, the median fluorescence intensity (MFI) values obtained from SAB are frequently used in combination with quantitative significances for diagnostic purposes. To gauge the reproducibility of SAB results, we assessed the interlaboratory variability of MFI values using identical kits with reagents from the same lot and the manufacturer's protocol. Methods: Six serum samples containing HLA-specific antibodies were analyzed at five laboratories by using Lifecodes LSA Class I and Class II SAB kits (Immucor, USA) from the same lot, according to the manufacturer's protocol. We analyzed the concordance of qualitative results according to distinct MFI cutoffs (1,000, 3,000, 5,000, and 10,000), and the correlation of quantitative MFI values obtained by the participating laboratories. The CV for MFI values were analyzed and grouped by mean MFI values from the five laboratories ( Results: The categorical results obtained from the five laboratories exhibited concordance rates of 96.0% and 97.2% for detection of HLA class I and class II antibodies, respectively. The Pearson correlation coefficients for MFI values of class I and class II antibodies were between 0.947-0.991 and 0.992-0.997, respectively. The median CVs for the MFI values among five laboratories in the lower MFI range ( Conclusions: Analysis of SAB performed in five laboratories using identical protocols and reagents from the same lot resulted in high levels of concordance and strong correlation of results.
机译:背景:尽管单抗原珠测定(SAB)是经过批准的定性测试,但从SAB获得的中值荧光强度(MFI)值经常与定量意义结合使用以进行诊断。为了评估SAB结果的可重复性,我们使用相同试剂盒以及相同批次和制造商规程的试剂,评估了MFI值在实验室间的变异性。方法:根据制造商的规程,使用来自同一批次的Lifecodes LSA I类和II类SAB试剂盒(美国Immucor),在五个实验室中分析了六个含有HLA特异性抗体的血清样品。我们根据不同的MFI临界值(1,000、3,000、5,000和10,000)以及参与实验室获得的定量MFI值的相关性,分析了定性结果的一致性。分析了MFI值的CV并按来自五个实验室的平均MFI值进行分组(结果:从五个实验室获得的分类结果显示,检测HLA I类和II类抗体的一致性分别为96.0%和97.2%。 I类和II类抗体的MFI值的皮尔逊相关系数分别在0.947-0.991和0.992-0.997之间。五个MFI范围较低的实验室中MFI值的中值CV(结论:五个实验室进行了SAB分析实验室使用相同的实验方案和同一批中的试剂,可产生很高的一致性,并且结果之间的相关性强。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号