首页> 外文期刊>Annals of laboratory medicine. >Evaluation of the Luminex ARIES HSV 1&2 Assay and Comparison with the FTD Neuro 9 and In-house Real-Time PCR Assays for Detecting Herpes Simplex Viruses
【24h】

Evaluation of the Luminex ARIES HSV 1&2 Assay and Comparison with the FTD Neuro 9 and In-house Real-Time PCR Assays for Detecting Herpes Simplex Viruses

机译:Luminex ARIES HSV 1&2分析的评估以及与FTD Neuro 9和用于检测单纯疱疹病毒的内部实时PCR分析的比较

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Background Human herpes simplex virus type 1 (HSV-1) and type 2 (HSV-2) are responsible for a plethora of human diseases, of which cutaneous and mucocutaneous infections are the most prevalent. In its most severe form, HSV infection can cause meningitis/encephalitis. We compared the Luminex ARIES HSV 1&2 assay (Luminex Corp., Austin, TX, USA), an automated sample-to-result molecular solution, to two non-automated HSV DNA assays. Methods A total of 116 artificial controls were used to determine the analytical performance of the ARIES assay. Controls were prepared by spiking universal transport medium (UTM) and cerebrospinal fluid (CSF) samples from patients who tested negative for HSV by an in-house HSV-1 and -2 DNA assay with reference materials (SeraCare Life Sciences, MA, USA; ZeptoMetrix Corp., MA, USA). Another 117 clinical samples were then used to compare the clinical performance of the ARIES assay with those of an in-house assay and the FTD Neuro 9 assay (Fast Track Diagnostics, Junglinster, Luxembourg). Results The analytical sensitivity (95% limit of detection) of the ARIES assay was 318 copies/mL (UTM samples) and 935 copies/mL (CSF samples) for HSV-1 strain 96 and 253 copies/mL (UTM samples) and 821 copies/mL (CSF samples) for HSV-2 strain 09. No cross-reactivity was observed in samples spiked with 14 non-HSV microorganisms. Compared with the reference result (agreement between the in-house and FTD Neuro 9 results), the ARIES assay had overall concordance rates of 98.2% (111/113) and 100% (113/113) for HSV-1 and HSV-2, respectively. Conclusions The ARIES assay appears to be an excellent alternative for rapid detection and differentiation of HSV in skin and genital infections, meningitis, and encephalitis.
机译:背景技术人类1型单纯疱疹病毒(HSV-1)和2型单纯疱疹病毒(HSV-2)导致多种人类疾病,其中皮肤和粘膜皮肤感染最为普遍。 HSV感染最严重的形式可引起脑膜炎/脑炎。我们将Luminex ARIES HSV 1&2分析(Luminex Corp.,奥斯汀,德克萨斯州,美国)(一种自动的样品到结果分子溶液)与两种非自动化的HSV DNA分析进行了比较。方法总共使用116个人工对照来确定ARIES测定的分析性能。通过掺入通用运输介质(UTM)和脑脊髓液(CSF)样品制备对照品,这些患者通过内部HSV-1和-2 DNA检测与参考材料一起检测为HSV阴性(美国马萨诸塞州SeraCare Life Sciences;美国马萨诸塞州ZeptoMetrix Corp.)。然后,使用另外117个临床样品将ARIES分析与内部分析和FTD Neuro 9分析(Fast Track Diagnostics,Junglinster,卢森堡)的临床性能进行比较。结果ARIES测定的HSV-1菌株96和253拷贝/ mL(UTM样品)的分析灵敏度(检测极限为95%)为318拷贝/ mL(UTM样品)和935拷贝/ mL(CSF样品)和821拷贝/ mL(UTM样品) HSV-2菌株09的拷贝数/ mL(CSF样品)。在掺有14种非HSV微生物的样品中未观察到交叉反应。与参考结果(内部和FTD Neuro 9结果达成协议)相比,ARIES测定的HSV-1和HSV-2总体一致性率为98.2%(111/113)和100%(113/113) , 分别。结论ARIES检测似乎是快速检测和区分皮肤和生殖器感染,脑膜炎和脑炎中HSV的极佳替代方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号