首页> 外文期刊>Annals of Intensive Care >Use of ultrasound-measured internal jugular vein collapsibility index to determine static intracardiac pressures in patients with presumed pulmonary hypertension
【24h】

Use of ultrasound-measured internal jugular vein collapsibility index to determine static intracardiac pressures in patients with presumed pulmonary hypertension

机译:使用超声测量的颈内静脉可折叠性指数确定假定的肺动脉高压患者的静态心内压

获取原文
           

摘要

Abstract BackgroundBedside ultrasound helps to estimate volume status in critically ill patients and has traditionally relied on diameter, respiratory variation, and collapsibility of the inferior vena cava (IVC) to reflect fluid status. We evaluated collapsibility of the internal jugular vein (IJ) with ultrasound and correlated it with concomitant right heart catheterization (RHC) measurements in patients with presumed pulmonary hypertension.Methods and resultsWe studied 71 patients undergoing RHC for evaluation of pulmonary hypertension. Using two-dimensional ultrasound (Sonosite, Washington, USA), we measured the diameter of the IJ at rest, during respiratory variation, and during manual compression. Collapsibility index during respiration (respiratory CI) and during manual compression (compression CI) was calculated. We correlated mean right atrial pressure (mRAP) and pulmonary artery occlusion pressure (PAOP) defined by RHC measurements with respiratory and compression CI. A secondary goal was examining correlations between CI calculations and B-type natriuretic peptide (BNP) levels. Baseline characteristics demonstrated female predominance ( n =?51; 71.8%), mean age 59.5?years, and BMI 27.3. There were significant correlations between decrease in compression CI and increase in both mRAP (Spearman: ??0.43; p value?=?0.0002) and PAOP (Spearman: ??0.35; p value?=?0.0027). In contrast, there was no significant correlation between respiratory CI and either mRAP (Spearman: ??0.14; p value?=?0.35) or PAOP (Spearman:??0.12; p value?=?0.31). We also observed significant negative correlation between compression CI and BNP (Spearman: ??0.31; p value?=?0.01) but not between respiratory CI and BNP (Spearman: ??0.12; p value?=?0.35).ConclusionIncreasing use of ultrasound has led to innovative techniques for estimating volume status. While prior ultrasound studies have used clinical parameters to estimate fluid status, our study used RHC measurements and demonstrated that compression CI potentially reflects directly measured mRAP and PAOP.
机译:摘要背景床边超声有助于估计危重患者的体液状态,传统上依靠直径,呼吸变化和下腔静脉(IVC)的可折叠性来反映体液状态。我们通过超声评估了颈内静脉(IJ)的可折叠性,并将其与估计的肺动脉高压患者同时进行的右心导管检查(RHC)相关联。使用二维超声(Sonosite,华盛顿,美国),我们测量了静息,呼吸变化和手动压迫期间IJ的直径。计算呼吸期间(呼吸CI)和手动按压期间(压缩CI)的可折叠性指数。我们将通过RHC测量定义的平均右心房压力(mRAP)和肺动脉闭塞压力(PAOP)与呼吸和压迫CI相关联。次要目标是检查CI计算与B型利钠肽(BNP)水平之间的相关性。基线特征显示女性占多数(n = 51; 71.8%),平均年龄59.5岁,BMI 27.3。压缩CI的降低与mRAP(Spearman:≥0.43; p值≥0.0002)和PAOP(Spearman:≥0.35; p值≥0.0027)之间存在显着的相关性。相反,呼吸CI与mRAP(Spearman:≤0.14; p值≤0.35)或PAOP(Spearman:≤0.12; p值≤0.31)之间无显着相关性。我们还观察到压缩CI和BNP之间的显着负相关(Spearman:0.31; p值= 0.01),但呼吸CI和BNP之间无显着负相关(Spearman:0.12; p值= 0.35)。超声波导致了估计体积状态的创新技术。虽然先前的超声研究已经使用临床参数来估计体液状况,但我们的研究使用了RHC测量值,并证明了压缩CI可能反映了直接测量的mRAP和PAOP。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号