首页> 外文期刊>Atmospheric Pollution Research >A model for performance of sulfite oxidation of ammonia-based flue gas desulfurization system
【24h】

A model for performance of sulfite oxidation of ammonia-based flue gas desulfurization system

机译:氨基烟气脱硫系统中亚硫酸盐氧化性能的模型

获取原文
   

获取外文期刊封面封底 >>

       

摘要

A mathematical model was developed to simulate the oxidation of total sulfite in the holding tank of ammonia-based flue gas desulfurization (FGD) system. The model could provide predictions of the oxidation ratio of total sulfite at different operating condition such as pH, concentration of total sulfur, air flow and residence time. The calculation results of an ammonia-based FGD system for 2??????150??MW boilers by this model were compared to that of corresponding measured values. The comparison results show that the simulated oxidation ratio of total sulfite agrees well with the measured data. The difference between calculated values and measured data is below 4.2%. This model appears to be beneficial for optimizing design and operation of total sulfite oxidation of an ammonia-based FGD system.
机译:建立了数学模型,以模拟氨基烟气脱硫(FGD)系统储罐中总亚硫酸盐的氧化。该模型可以预测不同工况下的亚硫酸盐的氧化率,例如pH,总硫浓度,空气流量和停留时间。将该模型对2×150 MW锅炉的氨基烟气脱硫系统的计算结果与相应的测量值进行了比较。比较结果表明,模拟的总亚硫酸盐氧化率与实测数据吻合良好。计算值与测量数据之间的差异低于4.2%。该模型对于优化基于氨的烟气脱硫系统的总亚硫酸盐氧化的设计和操作似乎是有益的。