Fluorometric Determination of Phospholipids by High-Performance Liquid Chromatography with Postcolumn On-Line Hydrolysis under UV-Irradiation, Phosphomolybdic Acid and Thiamine-Thiochrome Reactions

机译:高效液相色谱-紫外辐射,磷钼酸和硫胺-硫代色素反应后柱在线水解高效液相色谱法测定磷脂

获取原文
   

获取外文期刊封面封底 >>

       

摘要

A postcolumn phosphate-selective fluorescence detection system was developed for the determination of phospholipids by high-performance liquid chromatography. Phospholipids were separated on a silica gel column and then on-line hydrolyzed by photolysis in the presence of titanium dioxide under UV-irradiation (253.7 nm). The resultant orthophosphate was reacted with a molybdenum reagent to form phosphomolybdic acid, which was then reacted with the alkaline thiamine reagent. Finally, the fluorescence intensity of the resultant thiochrome converted from thiamine by phospho-molybdic acid was measured by setting the excitation wavelength at 380 nm and the emission wavelength at 442 nm. The calibration curves for phospholipids under the gradient elution programwere linear (correlation coefficient, 0.984 - 0.991) in the range 0.02 - 0.5 mg ml-1 (injection volume, 10 µl). When every 2 µg each of five phospholipids was repeatedly injected into this system, the relative standard deviations were between 4.14 and 4.76% (n=5).
机译:开发了一种柱后磷酸选择性荧光检测系统,用于通过高效液相色谱法测定磷脂。磷脂在硅胶柱上分离,然后在二氧化钛存在下于紫外线辐射(253.7 nm)下通过光解在线水解。使所得的正磷酸盐与钼试剂反应形成磷钼酸,然后使其与碱性硫胺素试剂反应。最后,通过将激发波长设置为380nm并且将发射波长设置为442nm,来测量通过硫磷钼酸从硫胺素转化的所得硫色素的荧光强度。梯度洗脱程序下磷脂的校准曲线是线性的(相关系数,0.984-0.991),范围为0.02-0.5 mg ml-1(进样量,10 µl)。当将五种磷脂中的每一种每2 µg重复注入该系统时,相对标准偏差在4.14和4.76%之间(n = 5)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号