首页> 外文期刊>Analytical methods >Analysis of latex protein content by liquid chromatography coupled with tandem mass spectrometry (HPLC/MS/MS)
【24h】

Analysis of latex protein content by liquid chromatography coupled with tandem mass spectrometry (HPLC/MS/MS)

机译:液相色谱-串联质谱(HPLC / MS / MS)分析乳胶蛋白含量

获取原文
           

摘要

In this work, the protein content of latex gloves and c-serum isolated from ammonia stabilized Hevea brasiliensis latex rubber concentrate was studied using a novel analytical protocol utilizing HPLC-ESI/MS/MS. Latex proteins were hydrolyzed to their corresponding building blocks and the resulting amino acid mixture was subsequently quantified by HPLC-ESI/MS/MS. Fifteen underivatized amino acids were separated with a hydrophilic interaction column (ZIC-HILIC) and the sample protein content was calculated. By utilizing a very specific and selective detection method (selected reaction monitoring mode) it was possible to minimize interferences from the sample matrix. For the natural rubber latex concentrate c-serum, the proteins were precipitated with trichloroacetic acid (TCA) and extracted with ammonia solution in water before hydrolysis. This procedure eliminated a large portion of c-serum rubber which interfered with the hydrolysis reaction. A c-serum protein concentration of 11.68 ?± 0.43 mg mla?’1 was obtained. The highest value available in the literature is 7.62 ?± 0.28 mg mla?’1 a€“ these results prove the high efficiency of the developed analytical protocol. Data obtained for the c-serum were used to estimate the efficiency of different protein extraction methods from the latex gloves. Thus, the results obtained in this work were used to link the protein content of the raw material with the protein content of the vulcanized latex gloves for the first time. Afterwards, the optimized protocol was used to evaluate the performance of different protein removal methods, utilized during latex glove manufacturing. Thus, a practical application of the developed method is presented.
机译:在这项工作中,使用新型分析方法,采用HPLC-ESI / MS / MS,研究了从氨稳定的巴西橡胶树胶乳浓缩物中分离得到的乳胶手套和c血清的蛋白质含量。乳胶蛋白水解成其相应的结构单元,然后通过HPLC-ESI / MS / MS对所得的氨基酸混合物进行定量。用亲水相互作用柱(ZIC-HILIC)分离了15种未衍生的氨基酸,并计算了样品蛋白质含量。通过使用非常特定的选择性检测方法(选定的反应监测模式),可以最大程度地减少样品基质的干扰。对于天然橡胶胶乳浓缩液c血清,蛋白质在水解前用三氯乙酸(TCA)沉淀,并用氨水溶液萃取。该程序消除了大部分的c-血清橡胶,它们干扰了水解反应。获得的c血清蛋白浓度为11.68±0.43mg mla-1。文献中提供的最高值为7.62±0.28 mg mla-1'a这些结果证明了开发的分析规程的高效率。从c血清获得的数据用于估计从乳胶手套提取不同蛋白质的方法的效率。因此,这项工作中获得的结果首次用于将原材料的蛋白质含量与硫化胶乳手套的蛋白质含量联系起来。然后,使用优化的方案评估乳胶手套制造过程中使用的不同蛋白质去除方法的性能。因此,提出了所开发方法的实际应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号