首页> 外文期刊>Analytical methods >Applicability of the bismuth bulk rotating disk electrode for heavy metal monitoring in undisturbed environmental and biological samples: determination of Zn(II) in rainwater, tap water and urine
【24h】

Applicability of the bismuth bulk rotating disk electrode for heavy metal monitoring in undisturbed environmental and biological samples: determination of Zn(II) in rainwater, tap water and urine

机译:铋散装圆盘电极在未受干扰的环境和生物样品中用于重金属监测的适用性:雨水,自来水和尿液中锌(II)的测定

获取原文
           

摘要

The bismuth bulk rotating disk electrode (BiB-RDE) is investigated here as a new and advantageous alternative to determine heavy metal ions in undisturbed environmental and biological samples (pH 7.5) by anodic stripping voltammetry, with demonstrated applicability to the determination of Zn(II) in rainwater, tap water and urine. The proposed method benefits from the insensitiveness of the bismuth bulk electrode to the Bi(III) hydrolysis that affects the common a€?in situa€? Bi film approach preventing its use at intermediate to alkaline pH. Instrumental parameters such as the rotation speed, deposition time, frequency, amplitude and step potential were optimized for Zn(II) and Cd(II) stripping signal enhancement. The stripping response is linear in the 20a€“160 ??g La?’1 concentration range (for 120 s deposition) with detection limits of 8.09 and 11.5 ??g La?’1 for Zn(II) and Cd(II), respectively. The accuracy of the results obtained was assessed successfully for Zn(II) determination by voltammetric measurements of surface water and wastewater certified reference materials. Applicability to Zn(II) determination in rainwater, tap water and urine was demonstrated by a good correlation with ICP-MS. Our results open a new application field for stripping voltammetry at bismuth electrodes, for heavy metal determination and speciation in environmental and biological samples.
机译:本文研究了铋块旋转圆盘电极(BiB-RDE)作为通过阳极溶出伏安法测定不受干扰的环境和生物样品(pH 7.5)中重金属离子的一种新的且有利的替代方法,已证明其可用于测定Zn(II) )在雨水,自来水和尿液中。所提出的方法得益于铋本体电极对Bi(III)水解的不敏感性,而Bi(III)水解会影响现场的常见情况。双膜方法阻止其在中等至碱性pH值下使用。仪器参数,如转速,沉积时间,频率,幅度和阶跃电位已针对Zn(II)和Cd(II)剥离信号增强进行了优化。在20a?160 ?? g La?'1浓度范围内(用于120 s沉积),汽提响应是线性的,对于Zn(II)和Cd(II)的检测极限分别为8.09和11.5 ?? g La?'1 , 分别。通过伏安法测量地表水和废水认证的参考物质,成功评估了所获得结果的准确性,用于锌(II)的测定。与ICP-MS的良好相关性证明了其在雨水,自来水和尿液中Zn(II)测定中的适用性。我们的结果为铋电极上溶出伏安法,环境和生物样品中重金属的测定和形态分析开辟了一个新的应用领域。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号