Two independent sampling and analytical methods for ortho-phthalaldehyde (OPA) in air have been developed, evaluated and compared: (1) a reagent-coated solid sorbent HPLC-UV method and (2) an impinger-fluorescence method. In the first method, air sampling is conducted at 1.0 L mina?’1 with a sampler containing 350 mg of silica gel coated with 1 mg of acidified 2,4-dinitrophenylhydrazine (DNPH). After sampling, excess DNPH in ethyl acetate is added to the sampler prior to storage for 68 hours. The OPAa€“DNPH derivative is eluted with 4.0 mL of dimethyl sulfoxide (DMSO) for measurement by HPLC with a UV detector set at 385 nm. The estimated detection limit is 0.016 ??g per sample or 0.067 ??g ma?’3 (0.012 ppb) for a 240 L air sample. Recoveries of vapor spikes at levels of 1.2 to 6.2 ??g were 96 to 101%. Recoveries of spikes as mixtures of vapor and condensation aerosols were 97 to 100%. In the second method, air sampling is conducted at 1.0 L mina?’1 with a midget impinger containing 10 mL of DMSO solution containing N-acetyl-L-cysteine and ethylenediamine. The fluorescence reading is taken 80 min after the completion of air sampling. Since the time of taking the fluorescence reading is critical, the reading is taken with a portable fluorometer. The estimated detection limit is 0.024 ??g per sample or 0.1 ??g ma?’3 (0.018 ppb) for a 240 L air sample. Recoveries of OPA vapor spikes at levels of 1.4 to 5.0 ??g per sample were 97 to 105%. Recoveries of spikes as mixtures of vapors and condensation aerosols were 95 to 99%. The collection efficiency for a mixture of vapor and condensation aerosol was 99.4%. The two methods were compared side-by-side in a generation system constructed for producing controlled atmospheres of OPA vapor in air. Average air concentrations of OPA vapor found by both methods agreed within ?±10%.
机译:已经开发,评估和比较了两种独立的空气中邻苯二甲醛(OPA)采样和分析方法:(1)试剂涂覆的固体吸附剂HPLC-UV方法和(2)聚酰亚胺荧光法。在第一种方法中,空气采样是在一个采样器中进行的,采样率为1.0 L min-1,采样器包含350 mg硅胶,并涂有1 mg酸化的2,4-二硝基苯肼(DNPH)。采样后,将过量的DNPH乙酸乙酯溶液添加到采样器中,然后保存68小时。用4.0 mL的二甲基亚砜(DMSO)洗脱OPAa?DNPH衍生物,以通过HPLC和设置在385 nm的UV检测器进行测定。估计的检出限为每个样品0.016μgg或对于240 L空气样品为0.067μgma·3 3(0.012 ppb)。 1.2至6.2 ?? g的蒸汽峰值回收率为96%至101%。作为蒸汽和冷凝气溶胶混合物的加标回收率为97%至100%。在第二种方法中,空气采样是在一个小型撞击器上以1.0 L min?-1进行的,该撞击器包含10 mL含有N-乙酰基-L-半胱氨酸和乙二胺的DMSO溶液。空气采样完成后80分钟获取荧光读数。由于获取荧光读数的时间很关键,因此使用便携式荧光计进行读数。估计的检出限为每个样品0.024 ?? g或对于240升空气样品为0.1 ?? g ma?3(0.018 ppb)。每个样品中OPA蒸气峰含量为1.4至5.0 ?? g的回收率为97%至105%。蒸气和冷凝气溶胶混合物的加标回收率为95%至99%。蒸汽和冷凝气溶胶混合物的收集效率为99.4%。在构建用于在空气中产生受控气氛的OPA蒸气的生成系统中,对这两种方法进行了比较。两种方法测得的OPA蒸气的平均空气浓度在±10%之内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号