A novel glucose biosensor based on the catalytic effect of platinum nanoparticles (PtNPs) on the enzymatic reaction for the glucose determination has been developed. PtNPs were in-situ synthesized on the surface of the eggshell membrane (ESM) upon which glucose oxidase (GOx) had been simultaneously immobilized accompanied by the synthesis of the PtNPs to produce a GOx-PtNPs/ESM. The glucose biosensor was fabricated by positioning the GOx-PtNPs/ESM on the surface of a dissolved oxygen sensor. The glucose concentration was quantified by the decrease of dissolved oxygen. The effect of the amount of K2PtCl4 (0.1??M), the volume of the GOx (1%, w/v), reaction time, pH, phosphate buffer concentration and temperature on the response of the glucose biosensor were studied in detail. This biosensor exhibited a response time of less than 30??s, a wide linear concentration range of 10a€“225 ??M and a detection limit of 5 ??M, good repeatability (RSD = 1.03%, n = 10), and satisfactory reproducibility (RSD = 0.54%, n = 5). The biosensor retained 90.0% of its initial response after 8 months at 25 ?°C. Common interferents such as D-fructose, citric acid, sucrose, L-ascorbic acid and so on did not any give significant interference. The proposed biosensor was successfully applied for the determination of glucose concentration in human blood serum with recoveries between 93.6% and 102.8%.
机译:基于铂纳米颗粒(PtNPs)对酶促反应的催化作用进行葡萄糖测定的新型葡萄糖生物传感器已经开发出来。在蛋壳膜(ESM)的表面上原位合成PtNP,同时将葡萄糖氧化酶(GOx)固定在其上,同时合成PtNP以产生GOx-PtNPs / ESM。通过将GOx-PtNPs / ESM放置在溶解氧传感器的表面来制造葡萄糖生物传感器。通过溶解氧的减少来定量葡萄糖浓度。详细研究了K2PtCl4(0.1?M)的量,GOx的体积(1%,w / v),反应时间,pH,磷酸盐缓冲液浓度和温度对葡萄糖生物传感器响应的影响。该生物传感器的响应时间小于30 s,线性浓度范围为10a-225 225 M,检测极限为5 s M,重复性好(RSD = 1.03%,n = 10),和令人满意的重现性(RSD = 0.54%,n = 5)。在25°C下放置8个月后,该生物传感器保留了其90.0%的初始响应。 D-果糖,柠檬酸,蔗糖,L-抗坏血酸等常见干扰物均无明显干扰。所提出的生物传感器已成功用于测定人血清中的葡萄糖浓度,回收率在93.6%至102.8%之间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号