摘要

The reason for the prominent error in the hydroxyl radical detection method by UV-vis spectrophotometry with fast blue BB salt (FBBs) as the chromogenic agent was detected, and a modified method was proposed. The simultaneous extraction of FBBs in the diazosulfone extraction process was proven to have a distinct influence on the test results. In the modified method, FeSO4 was adopted to limit the extraction of FBBs by a toluene/butanol extraction agent, which sharply decreased the influence of FBBs on diazosulfone detection. The FBBs amount and extraction time played an important role in its extraction. The appropriate FBBs/MSIA ratio was 50, and the reasonable extraction time was 300 s for the modified method. ??OH concentration in the directional decomposition of the Fenton system was detected. The test error was about 7%. This method is quite significant to test ??OH quantificationally to better understand Fenton reaction mechanisms and promote the generation of ??OH.
机译:在以固蓝BB盐(FBBs)为显色剂的紫外可见分光光度法中检测羟自由基的方法中存在显着误差的原因,提出了一种改进的方法。重氮砜萃取过程中同时萃取FBB被证明对测试结果有明显的影响。在改进的方法中,采用FeSO4限制了甲苯/丁醇萃取剂对FBB的萃取,从而大大降低了FBB对重氮砜检测的影响。 FBB的含量和提取时间在其提取中起着重要作用。改进的方法,合适的FBB / MSIA比为50,合理的提取时间为300 s。检测了Fenton体系的定向分解中的ΔOH浓度。测试误差约为7%。该方法对于定量测试ΔOH以更好地理解Fenton反应机理并促进ΔOH的生成具有重要意义。