首页> 外文期刊>Analytical methods >Multiple headspace solid-phase micro-extraction for the total content determination of tetramethylpyrazine in various vinegar samples by GC-FID
【24h】

Multiple headspace solid-phase micro-extraction for the total content determination of tetramethylpyrazine in various vinegar samples by GC-FID

机译:顶空固相微萃取-GC-FID法测定各种食醋中四甲基吡嗪的总含量

获取原文
           

摘要

The total tetramethylpyrazine (TMP) content in vinegar samples could be detected by multiple HS-SPME coupled with GC-FID (MHS-SPME-GC-FID) as a routine method. Unlike the traditional HS-SPME method, only one working curve built with different levels of standard aqueous solutions in the MHS-SPME-GC-FID method was able to calibrate the total TMP level from different matrixes (calibration standards ranging from 0.05 to 5.00 μg mL?1, R2 = 0.9986). In addition, the developed method was sensitive to the determination of TMP in vinegars (the limit of detection of 1 μg L?1, the limit of quantification of 5 μg L?1). In addition, the excellent recovery at 0.10 μg mL?1, 1.00 μg mL?1 and 5.00 μg mL?1 of TMP (ranging from 81.01% to 113.5%) and good reproducibility of the method (inter-day RSD 7.79%, intra-day RSD 3.94%) confirmed that the developed method was accurate and stable for the analysis of vinegar samples. Moreover, the detection results in real samples were consistent with the results from the traditional HS-SPME-GC-FID corrected by external standard method. In conclusion, the uniqueness of the working curve and the absence of matrix effect in MHS-SPME-GC-FID method were useful for rapidly obtaining comparable data from liquid samples with different matrix.
机译:醋液样品中的总四甲基吡嗪(TMP)含量可以通过常规方法通过与HS-SPME结合GC-FID(MHS-SPME-GC-FID)进行检测。与传统的HS-SPME方法不同,MHS-SPME-GC-FID方法中只有一条使用不同含量的标准水溶液建立的工作曲线能够校准不同基质的总TMP含量(校准标准范围为0.05至5.00μg (mL = 1,R2 = 0.9986)。另外,所开发的方法对醋中TMP的测定非常敏感(检测极限为1μgL?1,定量极限为5μgL?1)。此外,TMP的0.10μgmL?1、1、1.00μgmL?1和5.00μgmL?1的优异回收率(范围从81.01%到113.5%)和良好的重现性(日间RSD为7.79%,内部天RSD为3.94%),证实了所开发的方法对醋样品的分析是准确且稳定的。此外,实际样品中的检测结果与通过外标法校正的传统HS-SPME-GC-FID的结果一致。总之,在MHS-SPME-GC-FID方法中,工作曲线的唯一性和不存在基质效应有助于快速从具有不同基质的液体样品中获得可比数据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号