A disposable enzymatic electrochemical biosensor for amperometric organophosphorus pesticide determination based on a screen-printed carbon electrode (SPCE) platform was successfully developed. The working electrode consists of acetylcholine esterase (AChE) immobilized onto the surface of multi-walled carbon nanotube (MWCNT), chitosan (CS) and gold nanoparticle (AuNP)-modified SPCE. Ferricyanide was used as a redox mediator in solution. Two linear dynamic response ranges from 0.01 to 10 μg L?1 and from 10 to 100 μg L?1 were found for paraoxon-ethyl, with a detection limit of 0.03 μg L?1 (calculated as the amount of pesticide resulting in 10% of enzyme inhibition). High sensitivity was achieved due to a synergistic effect of AuNPs and MWCNTs deposited on the SPCE surface. Moreover, 83% of enzyme activity was retained after a dry storage period of 49 days (4 °C). Finally, the results of the electrochemical biosensor for paraoxon-ethyl-spiked spinach sample analysis showed a good agreement with those obtained from conventional HPLC.
机译:成功开发了基于丝网印刷碳电极(SPCE)平台的用于测定有机磷农药安培的一次性酶促电化学生物传感器。工作电极由固定在多壁碳纳米管(MWCNT),壳聚糖(CS)和金纳米颗粒(AuNP)修饰的SPCE表面上的乙酰胆碱酯酶(AChE)组成。铁氰化物用作溶液中的氧化还原介体。对氧磷乙基有两个线性动态响应范围,分别为0.01至10μgL?1和10至100μgL?1,检出限为0.03μgL?1(按农药含量的10%计算)酶抑制作用)。由于AuNPs和MWCNTs沉积在SPCE表面上的协同作用,实现了高灵敏度。此外,在49天(4°C)的干燥储存期后,保留了83%的酶活性。最后,用于对氧磷乙基菠菜样品分析的电化学生物传感器结果与常规HPLC的结果吻合良好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号