Two enzyme-linked immunosorbent assays (ELISAs) for the determination of caffeine and cotinine in water samples were validated and evaluated for the analysis of river and wastewater samples. The caffeine ELISA shows an IC50 ranging from 2.21 to 2.73 ng mla?’1, a limit of detection (LOD) of 0.135 ng mla?’1 and cross-reacts with paraxanthine (CR% = 63), theophylline (CR% = 5.2), and theobromine (CR% = 2.8); while the cotinine ELISA shows an IC50 ranging from 0.38 to 0.45 ng mla?’1, a LOD of 0.047 ng mla?’1 and cross-reacts with 3a€2-hydroxycotinine (CR% = 32) and nicotine (CR% = 1.1). Calibration curves were constructed in buffer in the concentration range 0.175a€“5 ng mla?’1 for the caffeine ELISA and 0.05a€“5 ng mla?’1 for the cotinine ELISA. Precision and accuracy were also evaluated. For the two assays, repeatability and reproducibility, expressed as the relative standard deviation of the absorbance, were within 3% and 8%, respectively. From the spiking experiment, the recovery of caffeine found in river and wastewater was between 94a€“101% and 89a€“110%, respectively; while the recovery of cotinine found in river and wastewater was between 95a€“105% and 99a€“115%, respectively. Fifteen river water samples and four wastewater samples from different wastewater treatment plants (WWTPs) were analyzed by ELISA and confirmed by LC-MS/MS. Comparing the two methods a correlation coefficient of 0.935 was obtained, showing a small overestimation of the ELISAs with respect to LC-MS/MS.
机译:对用于测定水样中咖啡因和可替宁的两种酶联免疫吸附测定(ELISA)进行了验证和评估,以分析河流和废水中的样品。咖啡因ELISA显示IC50为2.21至2.73 ng mla?'1,检测限(LOD)为0.135 ng mla?'1,并与对位黄嘌呤(CR%= 63),茶碱(CR%= 5.2)发生交叉反应)和可可碱(CR%= 2.8);而可替宁ELISA显示的IC50为0.38至0.45 ng mla?'1,LOD为0.047 ng mla?'1,并与3a€2-羟基烟碱(CR%= 32)和尼古丁(CR%= 1.1)发生交叉反应)。在咖啡因ELISA中,在浓度范围为0.175a?5 ng mla?-1的缓冲液中建立校正曲线;对于可替宁ELISA,在浓度范围为0.05a?5ng?a?1的缓冲液中建立校正曲线。准确性和准确性也进行了评估。对于这两种测定,以吸光度的相对标准偏差表示的重复性和可重复性分别在3%和8%之内。通过加标实验,发现河水和废水中咖啡因的回收率分别为94a€101%和89a€110%。而在河流和废水中发现的可替宁的回收率分别在95a?105%和99a?115%之间。 ELISA分析了15个河水样品和来自不同废水处理厂(WWTP)的4个废水样品,并通过LC-MS / MS进行了确认。比较这两种方法,相关系数为0.935,表明相对于LC-MS / MS,ELISA的估计值偏高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号