A method for determination of aluminium phosphide (AlP) in fumigants by inductively coupled plasma optical emission spectrometry (ICP OES) is presented. An 8 hour hydrolysis in water achieved complete decomposition of AlP, with the released PH3 being absorbed in a medium of KMnO4/H2SO4. The solution was treated with NH2OH·HCl to reduce the excess MnO4? and the PO43? so formed was quantitated as P by ICP OES based on external calibration using the P(I) 213.618 nm emission line. A detection limit (3s, n = 10) of 0.26 g/100 g AlP and an LOQ (10s, n = 10) of 0.85 g/100 g AlP were realized. Ten commercial samples of fumigants were analysed, providing results in agreement with specifications of ~55–60 g/100 g and concordant with values generated by a spectrophotometric method, as evidenced by a paired t-test (95% confidence limit). This simple procedure has been adopted by the Paraná Institute of Technology – TECPAR (Curitiba, Brazil).
机译:提出了一种通过电感耦合等离子体发射光谱法(ICP OES)测定熏蒸剂中磷化铝(AlP)的方法。在水中水解8小时可实现AlP的完全分解,释放的PH3被KMnO4 / H2SO4介质吸收。该溶液用NH 2 OH·HCl处理以减少过量的MnO 4。和PO43?通过ICP OES,使用P(I)213.618 nm发射线,通过外部校准,将形成的P定量为P。实现了0.26 g / 100 g AlP的检出限(3s,n = 10)和0.85 g / 100 g AlP的LOQ(10s,n = 10)。分析了十种熏蒸剂的商业样品,其结果与〜55–60 g / 100 g的规格相符,并且与分光光度法产生的值一致,如配对t检验(95%置信限)所证明。巴拉那技术研究所(TECPAR)(巴西库里提巴)采用了这种简单的程序。