A Nano-Composite Based on Fe3O4@Styrene-Maleic Anhydride Copolymer as a Magnetic Sorbent for Preconcentration of Silver(I) Ion

机译:以Fe3O4 @苯乙烯-马来酸酐共聚物为磁吸附剂的纳米复合材料,用于银(I)离子的预浓缩

获取原文
           

摘要

A magnetic nano-composite based on modified styren-maleic anhydride copolymer and Fe3O4 nano-particles was introduced as a new sorbent for solid-phase extraction and preconcentration of trace levels of silver ion from aqueous solutions. The size and morphology of the nano-sorbent were characterized via X-ray diffraction analysis, scanning electron microscopy and Fourier transform infrared spectroscopy. Following its desorption with hydrochloric acid, silver was detected by flame atomic absorption spectrometry. Different variables affecting the separation/pre-concentration of the silver ion were optimized. Under the optimized conditions, the calibration graph was linear in the 1–200 μg L–1 concentration range, with a correlation coefficient of 0.9991. The limit of detection and relative standard deviation for six replicate determinations at a silver ion level of 100 μg L–1 were 0.3 μg L–1 and 1.1 %, respectively. The preconcentration factor and adsorption capacity of the sorbent for silver ion were 100 and 78.2 mg g–1, respectively. The accuracy of the method was confirmed by analyzing the certified reference material NIST SRM 1566b. The method was successfully applied to determine silver ion in water samples and in radiology films, and satisfactory recoveries were obtained in the range of 96.8–99.6 % for the spiked samples.
机译:介绍了一种基于改性苯乙烯-马来酸酐共聚物和Fe3O4纳米粒子的磁性纳米复合材料,作为固相萃取和从水溶液中预富集痕量银离子的新型吸附剂。通过X射线衍射分析,扫描电子显微镜和傅里叶变换红外光谱对纳米吸附剂的尺寸和形态进行了表征。用盐酸解吸后,通过火焰原子吸收光谱法检测到银。优化了影响银离子分离/预浓缩的不同变量。在最佳条件下,校准曲线在1–200μgL–1浓度范围内呈线性,相关系数为0.9991。在100μgL-1的银离子水平下进行六次重复测定的检测限和相对标准偏差分别为0.3μgL-1和1.1%。银离子吸附剂的预浓缩系数和吸附容量分别为100和78.2 mg g-1。该方法的准确性通过分析认证的参考材料NIST SRM 1566b得以确认。该方法已成功用于测定水样和放射线照相胶片中的银离子,加标样品的回收率在96.8%至99.6%之间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号