...
首页> 外文期刊>American Journal of Analytical Chemistry >Square-Wave Adsorptive Cathodic Stripping Voltammeteric Determination of Manganese (II) Using a Carbon Paste Electrode Modified with Montmorillonite Clay
【24h】

Square-Wave Adsorptive Cathodic Stripping Voltammeteric Determination of Manganese (II) Using a Carbon Paste Electrode Modified with Montmorillonite Clay

机译:蒙脱土修饰碳糊电极对方波吸附阴极溶出伏安法测定锰(II)

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Manganese is an essential micronutrient for all organisms; however at high concentrations it has a toxic effect. Manganese toxicity is a serious constraint to crop cultivation since it is taken-up by plants and can easily be passed into the food chain again causing symptoms of Parkinson’s disease. A fully validated square-wave adsorptive cathodic stripping voltammetry method has been developed for determination of Mn (II) as a complex with 2-(5’-bromo-2’-pyridylazo) 5-diethylaminophenol in aqueous solutions using a carbon paste electrode (CPE) modified with montmorillonite-Na clay. The results showed that the modified CPE (90% (w/w) graphite powder and 10% (w/w) montmorillonite-Na clay) exhibited excellent electrochemical activity towards the investigated Mn (II) complex in acetate buffer of pH = 5.0. Factors affecting the performance of the modified carbon paste electrode and the sensitivity of the described square- wave stripping voltammetry method, including the electrode composition, concentration of ligand, pulse parameters and preconcentration conditions were examined. A detection limit (S/N = 3) of 0.015μg·L-1 (2.73 × 10-10 mol·L-1) Mn (II) was achieved when a preconcentration time of 240 s was applied. Insignificant interferences from various inorganic and organic species were estimated. The described square-wave adsorptive cathodic stripping voltammetry method coupled with the modified carbon paste electrode has been successfully applied to Mn (II) analysis in different water samples.
机译:锰是所有生物必不可少的微量营养素。但是,高浓度时有毒作用。锰的毒性严重限制了作物的生长,因为它被植物吸收,并且很容易再次进入食物链,从而引起帕金森氏病的症状。已开发出一种经过充分验证的方波吸附阴极溶出伏安法,该方法使用碳糊电极(2-(5'-bromo-2'-吡啶基偶氮)5-二乙氨基苯酚以水溶液的形式测定Mn(II)的络合物( CPE)用蒙脱石钠粘土改性。结果表明,改性的CPE(90%(w / w)的石墨粉和10%(w / w)的蒙脱土-Na粘土)对pH = 7的醋酸盐缓冲液中的锰(II)配合物表现出优异的电化学活性。 5.0。检查了影响改性碳糊电极性能和上述方波溶出伏安法灵敏度的因素,包括电极组成,配体浓度,脉冲参数和预浓缩条件。当应用240 s的预浓缩时间时,检测限(S / N = 3)为0.015μg·L-1(2.73×10-10mol·L-1)Mn(II)。估计来自各种无机和有机物种的干扰很小。所描述的方波吸附阴极溶出伏安法与改性碳糊电极结合已成功应用于不同水样中的锰(II)分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号