首页> 外文期刊>Advances in Physics Theories and Applications >Studies on Control of Hazardous Noise from Portable 650 VA Power Generator
【24h】

Studies on Control of Hazardous Noise from Portable 650 VA Power Generator

机译:便携式650 VA发电机有害噪声控制研究。

获取原文
           

摘要

Experimental studies on the assessment and control of near-field noise levels due to the operation of a portable 650 VA power generator were undertaken at a residential building in Ara village, Moro local government, area of Kwara State. Smart sensor sound level meter AR824 (30-130 dB), meter rule and stop watch were used to measure the noise level produced at every two minutes risen time intervals for seven hundred and twenty minutes at ten different locations of one meter intervals. The background noise level of the environment was first taken and reported to be 47.60. The data obtained were analysed with Matlab R2010a. The results revealed that the 650 VA generating plant is safe for use when it is positioned at least 3 meters away to the building, offices, shops and so on.
机译:在Kwara州Moro地方政府的Ara村的一栋居民楼中,对便携式650 VA发电机运行引起的近场噪声水平进行评估和控制的实验研究。使用智能传感器声级计AR824(30-130 dB),计尺和秒表来测量每两分钟上升时间间隔产生的噪声水平,持续时间为720分钟,在十个不同的位置(一米间隔)。首先获取环境的背景噪声水平,并报告为47.60。用Matlab R2010a分析获得的数据。结果表明,将650 VA的发电厂放置在距建筑物,办公室,商店等至少3米的位置,可以安全使用。