...
首页> 外文期刊>Acta Cirurgica Brasileira >Anatomical study of the positioning of guide wires for the reconstruction of the two bands of the anterior cruciate ligament using transtibial technique
【24h】

Anatomical study of the positioning of guide wires for the reconstruction of the two bands of the anterior cruciate ligament using transtibial technique

机译:经胫骨技术重建前交叉韧带两条带的导丝定位的解剖学研究

获取原文

摘要

PURPOSE: To determine whether it is possible and the difficulty of anatomical placement of guide wires for reconstruction of the two bands of the anterior cruciate ligament using transtibial technique and to measure the angle and positioning of the anatomic tibial guide wires for this technique. METHODS: Ten cadaver knees were dissected and a guide wire was positioned in the center of origin and insertion of each band. Were collected measurements of the distance from: 1) the entry point of the guide wire on tibial tuberosity; 2) the medial end of the tibia; 3) the tibial articular surface. Were also measured the medial and caudal angles of the guide wires. RESULTS: For the anteromedial band the medial angle was 19±5o and the caudal was 44±4o.The distances were 20±2 mm from anterior tuberosity, 26±5 mm from the tibial plateau and 25±5 mm from the medial end of the tibia. For the posterolateral band the medial angle was 26±5o and the caudal one was 36±8°. The distances were 31±6 mm for the anterior tuberosity, 24±4 mm for the tibial plateau and 17±7 mm from the end of the tibia. CONCLUSIONS: It is possible to position the guide wires of the two bands to reconstruct the anterior cruciate ligament using transtibial technique. The parameters for the proper positioning of the guide wire from anteromedial band is caudal angle of 44o with entry point 20 mm from anterior tuberosity; for the posterolateral band the caudal angle is 36o; from the tibial tuberosity the distance is 31 mm. This technique is difficult to perform leaving its questionable reproducibility.
机译:目的:确定使用胫骨技术重建前交叉韧带的两个带是否可行以及在解剖学上放置导线的难度,并为此技术测量胫骨解剖导线的角度和位置。方法:解剖十具尸体膝盖,将一根导丝放置在原点中心,并插入各条带。收集以下距离的测量值:1)胫骨粗隆处导线的进入点; 2)胫骨内侧; 3)胫骨关节面。还测量了导丝的内角和尾角。结果:对于前内侧带,内侧角为19±5o,尾部为44±4o,距前结节20±2 mm,距胫骨平台的距离26±5 mm,距胫骨内侧端的距离25±5 mm胫骨。对于后外侧带,内侧角为26±5o,而尾侧为36±8°。前结节的距离为31±6 mm,胫骨平台的距离为24±4 mm,距胫骨末端的距离为17±7 mm。结论:有可能使用跨胫骨技术定位两条带的导丝以重建前交叉韧带。适当地将导线从前内侧带定位的参数是尾骨角为44o,进入点距前结节20 mm。后外侧带的尾角为36o;距胫骨结节的距离为31 mm。该技术难以执行,其可重复性令人怀疑。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号