Purpose: To evaluate a model for studying the toxicity in nervous tissue and meninges using ultrasound to guide needle insertion into the subarachnoid space of rabbits, with the objective of avoiding injuries triggered by the puncture and by intraneural injection of solutions. Methods: Forty-five adult female rabbits were divided into 3 groups (G): G1 underwent subarachnoid puncture, G2 underwent subarachnoid injection of saline solution and G3 underwent subarachnoid injection of 0.5% hyperbaric bupivacaine. A needle was inserted into the S1-S2 subarachnoid space guided by ultrasound. The sensitivity and motility of the animals were evaluated for 3 days, after which the animals were sacrificed for removal of lumbar and sacral portions of the spinal cord for histological examination by light microscopy and immunohistochemistry. Results: All animals had motor function and pain sensitivity on the evaluation period. No animal had complication during or after the procedures. Conclusion: Ultrasound is a useful and safe method for the correct identification of the subarachnoid space of rabbits.
机译:目的:评估一种使用超声引导针头插入兔蛛网膜下腔的神经组织和脑膜毒性的模型,目的是避免穿刺和神经内注射溶液引起的伤害。方法:45只成年雌兔分为3组(G组):G1进行蛛网膜下腔穿刺,G2进行蛛网膜下腔注射生理盐水,G3进行0.5%高压布比卡因蛛网膜下腔注射。在超声引导下将针插入S1-S2蛛网膜下腔。评价动物的敏感性和运动力3天,然后处死动物以去除脊髓的腰部和部,以通过光学显微镜和免疫组织化学进行组织学检查。结果:在评估期间,所有动物均具有运动功能和疼痛敏感性。在手术期间或之后,没有动物发生并发症。结论:超声是正确鉴定兔蛛网膜下腔的一种有用且安全的方法。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号