An Electrochemical Sensing Platform Based on Iridium Oxide for Highly Sensitive and Selective Detection of Nitrite and Ascorbic Acid

机译:基于氧化铱的电化学传感平台用于亚硝酸盐和抗坏血酸的高灵敏度和选择性检测

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Iridium oxide (IrO x ) was electrodeposited onto glassy carbon electrode applying two-step potential cycling procedure. The electrocatalytic properties of the modified electrode IrO x /GC were evaluated with regards to electrochemical oxidation of nitrite and ascorbic acid (AA). The developed electrode-catalyst have been extensively studied by various electrochemical techniques. Differential pulse voltammetry (DPV) experiments indicated that the modified electrode possesses excellent electrocatalytic activity towards the oxidation of both nitrite and AA in neutral medium and offers simultaneous quantification of these substances. Constant potential amperometry studies also were performed – the IrO x /GC showed sensitive response to nitrite (159.7 μA mM –1 cm –2 ) with a wide linear range from 0.002 to 10 mM at 0.77 V (vs. Ag/AgCl, 3 M KCl), and to AA (96.2 μA mM –1 cm –2 ) with a linear range from 0.01 to 3 mM at 0.025 V. The detection limit was 0.63 μM nitrite and 4 μM AA, respectively, and both of them had fast response within 5 s. Considering the simple and rapid electrodeposition procedure for preparation, IrO x /GC is a new electrode-catalyst for sensitive and selective quantitative detection of nitrite and AA. The wide linear range, good selectivity, reproducibility of the amperometric response and long-time stability of the IrO x /GC make it a promising sensing material for practical nonenzymatic quantitative detection of nitrite and AA.
机译:使用两步电势循环程序将氧化铱(IrO x)电沉积到玻璃碳电极上。关于亚硝酸盐和抗坏血酸(AA)的电化学氧化,评估了改性电极IrO x / GC的电催化性能。已经通过各种电化学技术对开发的电极催化剂进行了广泛的研究。差示脉冲伏安法(DPV)实验表明,修饰的电极对中性介质中亚硝酸盐和AA的氧化均具有出色的电催化活性,并且可以同时定量这些物质。还进行了恒电位安培法研究– IrO x / GC显示了对亚硝酸盐(159.7μAmM –1 cm –2)的敏感响应,在0.77 V(vs. Ag / AgCl,3 M)的线性范围很宽,为0.002至10 mM KCl)和AA(96.2μAmM –1 cm –2)在0.025 V时线性范围为0.01至3 mM。检测极限分别为0.63μM亚硝酸盐和4μMAA,并且它们都具有快速响应在5秒内。考虑到制备的简单而快速的电沉积程序,IrO x / GC是用于灵敏和选择性定量检测亚硝酸盐和AA的新型电极催化剂。 IrO x / GC的宽线性范围,良好的选择性,安培响应的可重复性和长期稳定性使它成为用于亚硝酸盐和AA实用非酶定量检测的有前途的传感材料。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号