Background:To evaluate the diagnostic accuracy of different radiographic methods in the assessment of proximal alveolar bone loss (ABL).Materials and Methods:ABL, the distance between cement-enamel junction and alveolar bone crest, was measured in 70 mandibular human teeth – directly on the mandibles (control), using conventional periapical radiography with film holders (Rinn XCP and Han-Shin), digital periapical radiography with complementary metal-oxide semiconductor sensor, conventional panoramic, and cone-beam computed tomography (CBCT). Three programs were used to measure ABL on the images: Image tool 3.0 (University of Texas Health Sciences Center, San Antonio, Texas, USA), Kodak Imaging 6.1 (Kodak Dental Imaging 6.1, Carestream Health?, Rochester, NY, USA), and i-CAT vision 1.6.20. Statistical analysis used ANOVA and Tukey's test at 5% significance level.Results:The tomographic images showed the highest means, whereas the lowest were found for periapical with Han-Shin. Controls differed from periapical with Han-Shin (P < 0.0001). CBCT differed from panoramic (P = 0.0130), periapical with Rinn XCP (P = 0.0066), periapical with Han-Shin (P < 0.0001), and digital periapical (P = 0.0027). Conventional periapicals with film holders differed from each other (P = 0.0007). Digital periapical differed from conventional periapical with Han-Shin (P = 0.0004).Conclusions:Conventional periapical with Han-Shin film holder was the only method that differed from the controls. CBCT had the closest means to the controls.
机译:背景:在评估近端牙槽骨缺损(ABL)时评估不同射线照相方法的诊断准确性。材料与方法:直接测量70颗下颌人牙上的水泥-牙釉质接合点与牙槽骨c之间的距离。在下颌骨(对照)上,使用带有胶卷固定器的常规根尖射线照相术(Rinn XCP和Han-Shin),带有互补金属氧化物半导体传感器的数字根尖射线照相术,常规全景和锥形束计算机体层摄影术(CBCT)。使用了三个程序来测量图像上的ABL:图像工具3.0(德克萨斯州大学健康科学中心,美国德克萨斯州圣安东尼奥市),柯达成像6.1(柯达牙科成像6.1,Carestream Health ?,美国纽约州罗彻斯特),和i-CAT视觉1.6.20。统计分析采用显着性水平为5%的方差分析和Tukey检验。结果:断层扫描图像显示的最高值,而汉新患者的根尖图像最低。对照与汉新的根尖周手术不同(P <0.0001)。 CBCT不同于全景(P = 0.0130),Rinn XCP根尖周(P = 0.0066),Han-Shin根尖周(P <0.0001)和数字根尖周(P = 0.0027)。带有膜片固定器的传统根尖互不相同(P = 0.0007)。结论:与传统汉密膜相比,数字式根尖法与传统汉普膜根尖法不同(P = 0.0004)。 CBCT最接近于对照。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号