Estimation of changes in nickel and chromium content in nickel-titanium and stainless steel orthodontic wires used during orthodontic treatment: An analytical and scanning electron microscopic study

机译:估计正畸治疗中使用的镍钛合金和不锈钢正畸丝中镍和铬含量的变化:分析和扫描电子显微镜研究

获取原文
           

摘要

Introduction:The biocompatibility of orthodontic dental alloys has been investigated over the past 20 years, but the results have been inconclusive. The study compares standard 3 M Unitek nickel-titanium (NiTi) and stainless steel archwires with locally available JJ orthodontics wires. Scanning electron microscope (SEM) study of surface changes and complexometric titration to study compositional change was performed.Materials and Methods:Ten archwires each of group 1–3 M 0.016” NiTi, group 2-JJ 0.016” NiTi, group 3–3 M 0.019” *0.025” SS and group 4-JJ SS contributed a 10 mm piece of wire for analysis prior to insertion in the patient and 6 weeks post insertion. SEM images were recorded at ×2000, ×4000 and ×6000 magnification. The same samples were subjected to complexiometric titration using ethylenediaminetetraacetic acid to gauge the actual change in the composition.Observations and Results:The SEM images of all the archwires showed marked changes with deep scratches and grooves and dark pitting corrosion areas post intraoral use. 3M wires showed an uniform criss-cross pattern in as received wires indicating a coating which was absent after intraoral use. There was a significant release of Nickel and Chromium from both group 3 and 4. Group 2 wires released ions significantly more than group 1 (P = 0.0).Conclusion:Extensive and stringent trials are required before certifying any product to be used in Orthodontics.
机译:简介:在过去的20年中,对正畸牙科合金的生物相容性进行了研究,但结果尚无定论。这项研究将标准的3 M Unitek镍钛合金(NiTi)和不锈钢弓丝与当地的JJ牙齿矫正丝进行了比较。材料和方法:十根弓丝,分别为1-3 M 0.016” NiTi组,2-JJ 0.016” NiTi组,3-3 M组0.019“ * 0.025” SS和4-JJ SS组在插入患者体内之前和插入后6周内贡献了10毫米的金属丝用于分析。 SEM图像以×2000,×4000和×6000放大倍数记录。相同的样品用乙二胺四乙酸进行络合滴定,以测定组成的实际变化。观察和结果:所有弓丝的SEM图像显示明显的变化,在口内使用后有深的划痕和凹槽以及深色的点蚀腐蚀区域。 3M线材在接收到的线材中显示出均匀的纵横交错图案,表明在口腔内使用后没有涂层。第3组和第4组均显着释放了镍和铬。第2组导线释放的离子比第1组释放的离子多得多(P = 0.0)。结论:在认证用于正畸的任何产品之前,需要进行广泛而严格的试验。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号