首页> 外文期刊>Contemporary Clinical Dentistry >A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitro study
【24h】

A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitro study

机译:由四种市售临时材料制成的牙冠边缘精度的比较评估:体外研究

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Purpose:The purpose of this in vitro study was to evaluate and compare the primary marginal accuracy of four commercially available provisional materials (Protemp 4, Luxatemp Star, Visalys Temp and DPI tooth moulding powder and liquid) at 2 time intervals (10 and 30 min).Materials and Methods:A customized stainless steel master model containing two interchangeable dies was used for fabrication of provisional crowns. Forty crowns (n = 10) were fabricated, and each crown was evaluated under a stereomicroscope. Vertical marginal discrepancies were noted and compared at 10 min since the start of mixing and then at 30 min.Observations and Results:Protemp 4 showed the least vertical marginal discrepancy (71.59 μ), followed by Luxatemp Star (91.93 μ) at 10 min. DPI showed a marginal discrepancy of 95.94 μ while Visalys Temp crowns had vertical marginal discrepancy of 106.81 μ. There was a significant difference in the marginal discrepancy values of Protemp 4 and Visalys Temp. At 30 min, there was a significant difference between the marginal discrepancy of Protemp 4 crowns (83.11 μ) and Visalys Temp crowns (128.97 μ) and between Protemp 4 and DPI (118.88 μ). No significant differences were observed between Protemp 4 and Luxatemp Star.Conclusion:The vertical marginal discrepancy of temporary crowns fabricated from the four commercially available provisional materials ranged from 71 to 106 μ immediately after fabrication (at 10 min from the start of mix) to 83–128 μ (30 min from the start of mix). The time elapsed after mixing had a significant influence on the marginal accuracy of the crowns.
机译:目的:这项体外研究的目的是在两个时间间隔(10分钟和30分钟)中评估和比较四种市售临时材料(Protemp 4,Luxatemp Star,Visallys Temp和DPI牙粉和液体)的主要边缘精度。材料与方法:使用定制的包含两个可互换模具的不锈钢主模型制作临时表冠。制造了四十个冠(n = 10),并在体视显微镜下评估了每个冠。观察到垂直边际差异并在混合开始后的10分钟处进行比较,然后在30分钟时进行比较。观察与结果:Protemp 4的垂直边际差异最小(71.59μ),其次是Luxatemp Star(91.93μ)在10分钟时。 DPI的边际差异为95.94μ,而Visalys Temp牙冠的垂直边际差异为106.81μ。 Protemp 4和Visalys Temp的边际差异值存在显着差异。在30分钟时,Protemp 4冠的边缘差异(83.11μ)和Visalys Temp冠(128.97μ)之间以及Protemp 4和DPI(118.88μ)之间存在显着差异。 Protemp 4和Luxatemp Star之间没有观察到显着差异。结论:由四种市售临时材料制成的临时牙冠在制成后(混合开始10分钟后)的垂直边际差异为71至106μm。 –128μ(从混合开始30分钟)。混合后经过的时间对胎冠的边缘精度有重大影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号