Background: To assess the sensitivity and specificity of hemifield pattern electroretinogram (HF-PERG) for detecting early retinal ganglion cell (RGC) damage in ocular hypertensive (OH) patients.Methods: Fifty-two OH patients (mean age 56±9.6 years) with an intraocular pressure (IOP) >21 mmHg were assessed. All subjects underwent HF-PERG, optical coherence tomography (OCT), and frequency doubling technology (FDT) visual field.Results: OH patients showed a significant increase of peak-time of the N95 (P=0.027) compared to controls. The amplitude of the N95 of the lower and upper HF-PERG showed significant differences (P=0.037 and P=0.023, respectively) between the two groups. A significant intraocular (P=0.006) and interocular (P=0.018) asymmetry of N95 amplitude was found. Receiver operating characteristic (ROC) curve analysis revealed a sensitivity of 93% for the N95 of the lower HF-PERG, whereas full-field pattern electroretinogram (PERG) N95 peak-time had a sensitivity of 88%. In OH patients, we found a thinning of OCT - retinal nerve fiber layer (RNFL), especially in the superior and inferior quadrant, although not statistically significant, and a significantly higher FDT pattern standard deviation (FDT-PSD; P=0.001). In the OCT-RNFL inferior quadrant, a sensitivity of 82% was recorded. Finally, the sensitivity of the FDT-PSD was 92%.Conclusion: Our study shows that HF-PERG is a very sensitive test for detecting early damage of the RGC.
机译:背景:评估半场型视网膜电图(HF-PERG)检测高眼压(OH)患者的早期视网膜神经节细胞(RGC)损伤的敏感性和特异性方法:52例OH患者(平均年龄56±9.6岁)评估眼内压(IOP)> 21 mmHg。所有受试者均进行了HF-PERG,光学相干断层扫描(OCT)和倍频技术(FDT)视野。结果:与对照组相比,OH患者的N95峰值时间显着增加(P = 0.027)。上下HF-PERG的N95振幅在两组之间显示出显着差异(分别为P = 0.037和P = 0.023)。发现N95振幅存在明显的眼内(P = 0.006)和眼内(P = 0.018)不对称性。接收器工作特性(ROC)曲线分析显示,较低的HF-PERG的N95灵敏度为93%,而全场模式视网膜电图(PERG)N95峰值时间的灵敏度为88%。在OH患者中,我们发现OCT-视网膜神经纤维层(RNFL)变薄,特别是在上,下象限,尽管无统计学意义,并且FDT模式标准差明显更高(FDT-PSD; P = 0.001)。在OCT-RNFL下象限中,记录的灵敏度为82%。最后,FDT-PSD的灵敏度为92%。结论:我们的研究表明,HF-PERG是检测RGC早期损伤的非常敏感的测试。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号