首页> 外文期刊>Clinical ophthalmology >Home-based visual field test for glaucoma screening comparison with Humphrey perimeter
【24h】

Home-based visual field test for glaucoma screening comparison with Humphrey perimeter

机译:基于家庭视野的青光眼筛查与汉弗莱视野的比较

获取原文
           

摘要

Purpose: To present a home-based visual field examination method using a PC monitor or virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter, in order to assess the possibility of glaucoma screening through the Internet. Materials and methods: Software implementing a supra-threshold algorithm for the central 24° (52 points) of visual field at three threshold levels: 1) -4 db, 2) -8 db, and 3) -12 db, from the age-expected sensitivity was used for the purpose of testing. The software uses the web camera as a “virtual photometer” in order to detect room luminosity and allows self-testing using a computer monitor or virtual reality glasses using an Android smartphone with a 6-inch display. The software includes an expert system to analyze the visual field image and validate the reliability of the results. It also allows the physician to combine the results from two or more tests into a single test in order to achieve higher statistical accuracy of the final result. A total of ten patients, 20 eyes tested×52 points per eye=1,040 visual field test points, were compared point to point to those obtained using the Humphrey perimeter for the same patients, as they appeared randomly and consecutively at the glaucoma department within hours. Results: Good receiver operating characteristic/area under the curve coefficient was found, ranging from 0.762 to 0.837 ( P 0.001). Sensitivity ranged from 0.637 to 0.942, and specificity ranged from 0.735 to 0.497. Conclusion: The home-based visual field test exhibits a reasonable receiver operating characteristic curve when compared to the Humphrey perimeter, without the need of specialized equipment. The test may be useful for glaucoma screening.
机译:目的:提出一种使用PC监视器或虚拟现实眼镜的家庭视野检查方法,并通过将结果与汉弗莱(Humphrey)周边的结果进行比较来评估该方法的可靠性,以便评估通过互联网进行青光眼筛查的可能性。材料和方法:从年龄开始,针对三个阈值水平的中央24°(52点)视野实现超阈值算法的软件:1)-4 db,2)-8 db和3)-12 db -预期灵敏度用于测试目的。该软件将网络摄像头用作“虚拟光度计”,以检测房间的亮度,并允许使用计算机监视器进行自我测试,或使用具有6英寸显示屏的Android智能手机进行虚拟现实眼镜的自我测试。该软件包括一个专家系统,可以分析视野图像并验证结果的可靠性。它还可以使医生将两个或多个测试的结果合并为一个测试,以达到最终结果更高的统计准确性。总共10名患者,接受了20眼测试×每只眼睛52个点= 1,040个视野测试点,与在相同患者中使用汉弗莱视野获得的那些点对点进行比较,因为它们在数小时内随机并连续出现在青光眼部门。结果:曲线系数下的接收器工作特性/面积良好,范围为0.762至0.837(P <0.001)。灵敏度在0.637至0.942之间,特异性在0.735至0.497之间。结论:与汉弗莱周边相比,基于家庭的视野测试显示出合理的接收器工作特性曲线,而无需专用设备。该检查对于青光眼筛查可能有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号