首页> 外文期刊>Clinical ophthalmology >Reproducibility of measurements and variability of the classification algorithm of Stratus OCT in normal, hypertensive, and glaucomatous patients
【24h】

Reproducibility of measurements and variability of the classification algorithm of Stratus OCT in normal, hypertensive, and glaucomatous patients

机译:正常,高血压和青光眼患者的Stratus OCT测量结果的可重复性和分类算法的变异性

获取原文
           

摘要

Purpose: To assess the reproducibility of retinal nerve fiber layer (RNFL) measurements and the variability of the probabilistic classification algorithm in normal, hypertensive and glaucomatous eyes using Stratus optical coherence tomography (OCT).Methods: Forty-nine eyes (13 normal, 17 ocular hypertensive [OHT] and 19 glaucomatous) of 49 subjects were included in this study. RNFL was determined with Stratus OCT using the standard protocol RNFL thickness 3.4. Three different images of each eye were taken consecutively during the same session. To evaluate OCT reproducibility, coefficient of variation (COV) and intraclass correlation coefficient (ICC) were calculated for average thickness (AvgT), superior average thickness (Savg), and inferior average thickness (Iavg) parameters. The variability of the results of the probabilistic classification algorithm, based on the OCT normative database, was also analyzed. The percentage of eyes with changes in the category assigned was calculated for each group.Results: The 50th percentile of COV was 2.96%, 4.00%, and 4.31% for AvgT, Savg, and Iavg, respectively. Glaucoma group presented the largest COV for all three parameters (3.87%, 5.55%, 7.82%). ICC were greater than 0.75 for almost all measures (except from the inferior thickness parameter in the normal group; ICC = 0.64, 95% CI 0.334–0.857). Regarding the probabilistic classification algorithm for the three parameters (AvgT, Savg, Iavg), the percentage of eyes without color-code category changes among the three images was as follows: normal group, 100%, 84.6% and 92%; OHT group, 89.5%, 52.7%, 79%; and Glaucoma group, 82%, 70.6%, and 76.5%, respectively. A probabilistic category switch from pathologic to normal or vice versa was observed in three eyes (15.8%) of the glaucomatous group for the Savg parameter and in two eyes of the OHT group: one eye (5,9%) for the AvgT and one eye (5.9%) for the Savg parameter.Conclusions: OCT RNFL measurements showed a good reproducibility in normal, OHT, and glaucoma eyes. The probabilistic classification for the three main parameters showed certain variability, especially in glaucoma group and OHT group. Therefore, one isolated category result should be interpreted with caution before clinical classification of the patient.
机译:目的:使用Stratus光学相干断层扫描(OCT)评估正常,高血压和青光眼眼中视网膜神经纤维层(RNFL)测量结果的可重复性和概率分类算法的变异性。方法:四十九只眼(13眼,17眼这项研究包括49位受试者的高眼压[OHT]和19例青光眼。 RNFL由Stratus OCT使用标准协议RNFL厚度3.4确定。在同一会话中连续拍摄每只眼睛的三张不同图像。为了评估OCT的可重复性,计算了平均厚度(AvgT),上等平均厚度(Savg)和下等平均厚度(Iavg)参数的变异系数(COV)和组内相关系数(ICC)。还分析了基于OCT规范数据库的概率分类算法结果的可变性。计算各组类别变化的眼睛的百分比。结果:AvgT,Savg和Iavg的第50个百分位数的COV分别为2.96%,4.00%和4.31%。青光眼组在所有三个参数中均表现出最大的COV(3.87%,5.55%,7.82%)。几乎所有测量值的ICC均大于0.75(正常组中次厚度参数除外; ICC = 0.64,95%CI 0.334–0.857)。关于三个参数(AvgT,Savg,Iavg)的概率分类算法,在三个图像中没有颜色代码类别变化的眼睛百分比如下:正常组,100%,84.6%和92%; OHT组分别为89.5%,52.7%,79%;和青光眼组分别为82%,70.6%和76.5%。对于Savg参数,在青光眼组的三只眼(15.8%)和OHT组的两只眼中观察到了从病理性切换到正常的概率类别,反之亦然:结论:OCT RNFL测量显示正常,OHT和青光眼的重现性良好。三个主要参数的概率分类表现出一定的变异性,尤其是在青光眼组和OHT组。因此,在对患者进行临床分类之前,应谨慎解释一种孤立的分类结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号