首页> 外文期刊>Clinical Epidemiology >Validity and reproducibility of a physical activity questionnaire for older adults: questionnaire versus accelerometer for assessing physical activity in older adults
【24h】

Validity and reproducibility of a physical activity questionnaire for older adults: questionnaire versus accelerometer for assessing physical activity in older adults

机译:老年人身体活动量表的有效性和可重复性:用于评估老年人身体活动量的问卷调查表与加速度计

获取原文
       

摘要

Background: Physical activity (PA) is important in older adults for the maintenance of functional ability. Assessing PA may be difficult. Few PA questionnaires have been compared to activity monitors. We examined reproducibility and validity of the self-administered Longitudinal Ageing Study Amsterdam Physical Activity Questionnaire (LAPAQ) against a triaxial accelerometer (ACTR) (Sensewear? Pro) in older adults.Methods: Participants wore the ACTR continuously for two weeks. After 2 (T [time] = 1) and 4 (T = 2) weeks, participants completed the LAPAQ. Since the LAPAQ asks about 2 weeks’ worth of physical activity, the ACTR and LAPAQ coincided at T1. T2 was used to assess the reproducibility of the LAPAQ results only. We calculated Pearson’s correlation coefficients (PCC) to examine reproducibility and validity. For visualization, we used scatterplots and Bland–Altman plots. With a receiver operating characteristics (ROC) curve we assessed how well the LAPAQ identifies older adults whose activity level is below official recommendations.Results: A total of 89 persons were included. Of the participants, 48% were men; median age was 73, and median body mass index was 25. The 2-week mean total duration of activity was 2788 (ACTR, T = 1), 2439 (LAPAQ T = 1), and 1994 (LAPAQ T = 2) minutes. As a reference, 2 full weeks contained 20,160 minutes. Reproducibility of the LAPAQ was moderate (PCC 0.68, 95% CI 0.55–0.80). The median difference between LAPAQ at T = 1 and the ACTR (LAPAQ minus ACTR) was –510 minutes and the PCC was 0.25 (95% CI 0.07–0.44). The area under the ROC curve was 0.73 (95% CI 0.59–0.86).Conclusion: LAPAQ underestimates PA and seems unsuitable for exact measurement in older adults. However, it may be used to determine if a person’s PA level is below the recommended level.
机译:背景:体育活动(PA)在老年人中对于维持功能能力很重要。评估PA可能很困难。很少有PA调查表与活动监控器进行比较。我们检查了针对老年人的三轴加速度计(ACTR)(Sensewear?Pro)进行的纵向纵向衰老研究阿姆斯特丹身体活动问卷(LAPAQ)的可重复性和有效性。方法:参与者连续佩戴ACTR两周。在2(T [时间] = 1)和4(T = 2)周之后,参与者完成了LAPAQ。由于LAPAQ要求进行大约2周的体育锻炼,因此ACTR和LAPAQ在T1碰巧发生。 T2仅用于评估LAPAQ结果的可重复性。我们计算了Pearson的相关系数(PCC)以检查可重复性和有效性。为了进行可视化,我们使用了散点图和Bland-Altman图。通过接收器操作特征(ROC)曲线,我们评估了LAPAQ对活动水平低于官方建议的老年人的识别能力。结果:总共包括89人。在参与者中,有48%是男性。中位年龄为73岁,中位体重指数为25。2周平均总活动时间为2788(ACTR,T = 1),2439(LAPAQ T = 1)和1994(LAPAQ T = 2)分钟。作为参考,整整2周的时间为20,160分钟。 LAPAQ的重现性中等(PCC 0.68,95%CI 0.55-0.80)。 T = 1时LAPAQ与ACTR之间的中位数差异(LAPAQ减去ACTR)为–510分钟,PCC为0.25(95%CI 0.07–0.44)。 ROC曲线下的面积为0.73(95%CI 0.59–0.86)。结论:LAPAQ低估了PA,似乎不适合进行老年人的精确测量。但是,它可用于确定某人的PA水平是否低于建议水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号