首页> 外文期刊>Clinical ophthalmology >Visual field loss in schizophrenia: evaluation of magnocellular pathway dysfunction in schizophrenic patients and their parents
【24h】

Visual field loss in schizophrenia: evaluation of magnocellular pathway dysfunction in schizophrenic patients and their parents

机译:精神分裂症的视野丧失:评估精神分裂症患者及其父母的巨细胞通路功能障碍

获取原文
           

摘要

Purpose: We sought to evaluate the visual pathway deficits in schizophrenic patients, compared with their parents and healthy controls, using Matrix frequency doubling technology (FDT) perimetry. Matrix FDT is an ophthalmic test used to detect visual field loss. Method: A total of 13 patients, 13 parents, and 12 healthy controls were enrolled in the study. Participants were subjected to Matrix FDT perimetry in a single test session. We analyzed the mean deviation for each eye and used a generalized estimated equation to evaluate differences among the groups and correct the dependency between the eyes. Results: The global mean deviation (presented as the mean of both eyes) was significantly lower in the schizophrenic patients than in their parents or controls. Analysis of the general sensitivity of the fibers crossing the optic chiasm showed a difference between the groups (P = 0.006), indicating that the sensitivity of the fibers crossing the optic chiasm was lower than those which did not cross. But when we analyzed the specific groups, the difference between the fibers was not considerable. Comparison of the right and left hemispheres showed that general sensitivity was lower for the left hemisphere, but when we analyzed specific groups, the difference was not significant (P = 0.29). Conclusion: These findings are suggestive of a lower global sensitivity in schizophrenic patients and their parents compared with controls. This difference may be an endophenotype of schizophrenia. The present study adds to a growing body of research on early-stage visual processing deficits in schizophrenia.
机译:目的:我们试图使用矩阵倍频技术(FDT)视野测量法评估精神分裂症患者与其父母和健康对照者的视觉通路缺陷。 Matrix FDT是一种眼科测试,用于检测视野损失。方法:总共13名患者,13名父母和12名健康对照者参加了研究。在一次测试中对参与者进行Matrix FDT视野检查。我们分析了每只眼睛的平均偏差,并使用广义估计方程来评估组之间的差异并更正眼睛之间的依赖性。结果:精神分裂症患者的总体平均偏差(表示为两只眼睛的平均值)显着低于其父母或对照组。对穿过视交叉的纤维的总体敏感性的分析表明,各组之间存在差异(P = 0.006),这表明穿过视交叉的纤维的敏感性低于未交叉的纤维。但是,当我们分析特定的组时,纤维之间的差异并不大。左右半球的比较表明,左半球的总体敏感性较低,但是当我们分析特定组时,差异并不显着(P = 0.29)。结论:这些发现提示与对照组相比,精神分裂症患者及其父母的总体敏感性较低。这种差异可能是精神分裂症的内表型。本研究增加了关于精神分裂症的早期视觉加工缺陷的研究机构。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号