Novel Fecobionics Defecatory Function Testing

机译:新型Fecobionics排便功能测试

获取原文
       

摘要

INTRODUCTION:Defecation is a complex process that can be easily disturbed. Defecatory disorders may be diagnosed using specialized investigation, including anorectal manometry (ARM) and the balloon expulsion test (BET). Recently, we developed a simulated stool named Fecobionics that integrates several tests and assesses pressures, orientation, and bending during evacuation. The aim was to evaluate the feasibility and performance of Fecobionics for assessing defecatory physiology in normal subjects.METHODS:Physiological expulsion parameters were assessed in an interventional study design. The 10-cm-long Fecobionics probe contained pressure sensors at the front and rear and inside a bag and 2 motion processor units. The bag was distended in the rectum of 20 presumed normal subjects (15 female/5 male) until urge to defecate. ARM-BET was also performed. Three subjects used +2 minutes to evacuate BET, and 1 subject had a high fecal incontinence score. Therefore, the normal group consisted of 16 subjects (13 female/3 male aged 25–78 years).RESULTS:All subjects reported that Fecobionics evacuation was similar to normal defecation. Fecobionics expulsion pressure signatures demonstrated 5 phases, reflecting rectal pressure, anal relaxation, and anal passage. Preload-afterload loop diagrams demonstrated clockwise contraction cycles. The expulsion duration for BET and Fecobionics was 16 ± 2 and 23 ± 5 seconds (P > 0.2), respectively. The duration of the Fecobionics and BET expulsions was associated (P < 0.001). The change in bending of Fecobionics during defecation was 40 ± 3°.DISCUSSION:Fecobionics obtained reliable data under physiological conditions. Agreement was found for comparable variables between ARM-BET and Fecobionics but not for other variables. The study suggests that Fecobionics is safe and effective in evaluation of key defecatory parameters.
机译:简介:排便是一个很容易受到干扰的复杂过程。可以使用专门的检查来诊断排便障碍,包括肛门直肠测压(ARM)和球囊排泄测试(BET)。最近,我们开发了一个名为Fecobionics的模拟凳子,该凳子集成了多个测试并评估了疏散过程中的压力,方向和弯曲。目的是评估Fecobionics在正常受试者中评估排便生理的可行性和性能。方法:在干预性研究设计中评估了生理排出参数。 10厘米长的Fecobionics探头在袋的前后,袋内装有压力传感器和2个运动处理器单元。该袋子在20名假定的正常受试者的直肠中扩张(15名女性/ 5名男性),直到有排便的欲望。还进行了ARM-BET。 3名受试者使用+2分钟排空BET,而1名受试者的粪便失禁评分较高。因此,正常组由16名受试者组成(13名女性/ 3名男性,年龄在25-78岁之间)。结果:所有受试者均报告排异铁通与正常排便相似。 Fecobionics排出压力信号显示出5个阶段,反映了直肠压力,肛门松弛和肛门通过。预加载-后加载循环图展示了顺时针收缩周期。 BET和Fecobionics的驱逐时间分别为16±2和23±5秒(P> 0.2)。 Fecobionics和BET排出的持续时间相关(P <0.001)。排便期间Fecobionics的弯曲变化为40±3°。讨论:Fecobionics在生理条件下获得了可靠的数据。对于ARM-BET和Fecobionics之间的可比较变量发现一致,但对于其他变量则没有一致。该研究表明,Fecobionics在评估关键排便参数方面是安全有效的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号