首页> 外文期刊>Clinical and vaccine immunology: CVI >Effect of Sexually Transmitted Disease (STD) Coinfections on Performance of Three Commercially Available Immunosorbent Assays Used for Detection of Herpes Simplex Virus Type 2-Specific Antibody in Men Attending Baltimore, Maryland, STD Clinics
【24h】

Effect of Sexually Transmitted Disease (STD) Coinfections on Performance of Three Commercially Available Immunosorbent Assays Used for Detection of Herpes Simplex Virus Type 2-Specific Antibody in Men Attending Baltimore, Maryland, STD Clinics

机译:性传播疾病(STD)合并感染对三种男性巴尔的摩单纯疱疹病毒2型特异性抗体检测的市售免疫吸附测定性能的影响

获取原文
           

摘要

Two hundred seventy-nine serum samples from men attending sexually transmitted disease (STD) clinics in Baltimore, Maryland, were tested for herpes simplex virus type 2 (HSV-2)-specific antibody by three immunosorbent glycoprotein G-2-based assays (the Kalon, Focus, and Biokit assays). The results for all samples with positive results were confirmed by Western blotting (91/279; 32.6% HSV-2 seroprevalence). All patients were also tested for Chlamydia trachomatis, Neisseria gonorrhoeae, Trichomonas vaginalis, Mycoplasma genitalium, human immunodeficiency virus type 1, and hepatitis C virus. The Kalon assay performed very well with samples from this population (90.8% sensitive, 99.4% specific), whereas the Focus assay had a sensitivity (82.6%) much lower than that shown previously. For 19.7% of the samples, the Biokit assay gave an indeterminate result. It was found that the odds of a sample having a Biokit assay indeterminate result compared to that of having a definitive positive or negative results were 3.88 times greater for subjects concurrently infected with N. gonorrhoeae, after the effects of other STDs were controlled for (P = 0.001; 95% confidence interval, 1.78, 8.45). Unfortunately, we were unable to control for HSV-1 infection status in the regression model, which, on the basis of χ2 analysis, might also affect the clarity of the Biokit test. The recommended index cutoff value of 1.1 for the Focus and Kalon assays was found to be optimal for this population.
机译:通过三种基于免疫吸附糖蛋白G-2的检测方法(来自马里兰州巴尔的摩的性传播疾病(STD)诊所的男性)的279份血清样品中检测了2型单纯疱疹病毒(HSV-2)特异性抗体( Kalon,Focus和Biokit分析)。通过Western印迹证实了所有具有阳性结果的样品的结果(91/279; 32.6%HSV-2血清阳性率)。还对所有患者进行了沙眼衣原体感染,淋病奈瑟氏菌,阴道滴虫,生殖器支原体感染,人类免疫缺陷病毒类型的检测。 1,与丙型肝炎病毒有关。 Kalon分析在该人群中的样品表现很好(灵敏性为90.8%,特异度为99.4%),而Focus分析的灵敏性(82.6%)比以前显示的要低得多。对于19.7%的样品,Biokit分析得出的结果不确定。结果发现,与同时感染 N的受试者相比,具有Biokit试验结果不确定的样品与具有确定的阳性或阴性结果的样品的几率高3.88倍。在控制了其他性病的影响后,淋球菌 P = 0.001; 95%置信区间为1.78,8.45)。不幸的是,我们无法在回归模型中控制HSV-1感染状态,根据χ 2 分析,这也可能影响Biokit测试的清晰度。发现该人群的Focus和Kalon分析的推荐指数截止值为1.1。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号