首页> 外文期刊>Ciência Rural >Intraocular pressure measurements with the Tono-Pen XL? and Perkins? applanation tonometers in horses and cattle
【24h】

Intraocular pressure measurements with the Tono-Pen XL? and Perkins? applanation tonometers in horses and cattle

机译:使用Tono-Pen XL进行眼压测量和珀金斯?马和牛的压平眼压计

获取原文
           

摘要

The objective of this study was to compare the accuracy between two applanation tonometers, Tono-Pen XL? and Perkins?, in horses and cattle. The eyes of 20 horses and 20 cattle conscious and healthy were evaluated for the in vivo study and both eyes of 5 horses and 5 cattle were used as controls for the postmortem study. In conscious animals, the tonometry was performed with auriculopalpebral nerve block and then topical anesthesia for both tonometers and 1% fluorescein eye drops only for the Perkins tonometer. Readings of intraocular pressure (IOP) in the postmortem study were taken using manometry and tonometry by Tono-Pen XL? and Perkins?. The correlation coefficient (r2) between manometry and applanation tonometers Tono-Pen XL? and Perkins?, in horses, were 0.845 and 0.989, respectively, and in cattle, were 0.772 and 0.988, respectively. The mean IOP values in conscious horses with Tono-Pen XL? and Perkins? were 20.1±3.9mmHg and 20.9±3.2mmHg, respectively, and in conscious cattle, these values were 17.2±2.4mmHg and 17.9±1.4mmHg, respectively. There was a strong correlation between the IOP values obtained by direct ocular manometry and the Tono-Pen XL? and Perkins? tonometers in horses and cattle. There was no statistically significant difference between the mean IOPs obtained with both tonometers in conscious animals; however, there was a difference between the minimum values, which were on average 2-3 mmHg lower with the Tono-Pen XL? tonometer than with the Perkins? tonometer, which justifies a table of normal values differentiated for each tonometer.
机译:这项研究的目的是比较两个压平眼压计Tono-Pen XL?的准确性。和珀金斯?,在马和牛中。对20只马和20只清醒且健康的牛的眼睛进行了体内研究,并将5只马和5头牛的两只眼睛用作死后研究的对照。在有意识的动物中,先用耳睑神经神经阻滞进行眼压测定,然后对两个眼压计进行局部麻醉,仅对Perkins眼压计进行1%荧光素眼药水。验尸研究中眼压(IOP)的读数是通过Tono-Pen XL?使用测压法和眼压计获得的。和珀金斯?测压和压平眼压计之间的相关系数(r2)。马的Perkins和珀金斯α分别为0.845和0.989,牛的分别为0.772和0.988。 Tono-Pen XL在有意识的马中的平均IOP值?和珀金斯?分别为20.1±3.9mmHg和20.9±3.2mmHg,在有意识的牛中,这些值分别为17.2±2.4mmHg和17.9±1.4mmHg。通过直接眼压测量获得的IOP值与Tono-Pen XL?之间存在很强的相关性。和珀金斯?马和牛的眼压计。在有意识的动物中,两种眼压计获得的平均眼压之间均无统计学意义的差异。但是,最小值之间存在差异,而Tono-Pen XL的平均值要低2-3 mmHg?眼压计比与珀金斯计?眼压计,它证明了针对每个眼压计的正常值表。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号