首页> 外文期刊>Chinese Medicine >Simultaneous determination of multiple marker constituents in concentrated Gegen Tang granule by high performance liquid chromatography
【24h】

Simultaneous determination of multiple marker constituents in concentrated Gegen Tang granule by high performance liquid chromatography

机译:高效液相色谱法同时测定浓缩葛根汤颗粒中多种标志物成分

获取原文
       

摘要

Background Concentrated Gegen Tang (GT) granule is a widely available traditional Chinese medicinal product for the treatment of cold and flu. There was no reliable analytical method available for the quality assessment of GT granules. Methods An HPLC method with an Agilent Zorbax SB-Phenyl Stablebond column (250 × 4.6 mm, 5 μm) was developed and validated. The mobile phase gradient was a mixture of 0.1% trifluoroacetic acid (TFA) in acetonitrile (ACN) and 0.1% TFA in water. The detection with a diode-array detector was set at 207, 230, 250 and 275 nm. Seven components, namely puerarin, daidzein, paeoniflorin, cinnamic acid, glycyrrhizin, ephedrine and pseudoephedrine were selected as marker compounds for the evaluation. Results The regression equations revealed good linear relationships (correlation coefficients: 0.9994–0.9998) between the peak areas and concentrations. The recovery was between 98.8% and 101.7% with good precision and accuracy. The quality of GT granule from four different manufacturers was evaluated with this newly developed method. Samples from four manufacturers showed similar profiles but contents of the detected markers varied significantly among manufacturers and batches. Conclusion A new method using high performance liquid chromatography (HPLC) has been developed for simple and reliable quality control of commercial concentrated GT granules. Sensitivity was increased by multi-wavelength detection. The contents of selected marker components in GT granules varied significantly among manufacturers and batches, making it necessary to evaluate the quality of concentrated GT granules in the market.
机译:背景技术浓缩葛根汤(GT)颗粒是一种广泛使用的中药,可用于治疗感冒和流感。没有可靠的分析方法可用于GT颗粒的质量评估。方法开发并验证了使用Agilent Zorbax SB-苯基稳定键(250×4.6 mm,5μm)的HPLC方法。流动相梯度为乙腈(ACN)中的0.1%三氟乙酸(TFA)和水中的0.1%TFA的混合物。使用二极管阵列检测器的检测设置为207、230、250和275 nm。选择了葛根素,大豆苷元,pa药苷,肉桂酸,甘草甜素,麻黄碱和伪麻黄碱七个成分作为标记化合物进行评估。结果回归方程显示出峰面积与浓度之间具有良好的线性关系(相关系数:0.9994–0.9998)。回收率在98.8%至101.7%之间,具有良好的精度和准确性。使用这种新开发的方法评估了来自四个不同制造商的GT颗粒的质量。来自四个制造商的样品显示出相似的特征,但检测到的标记物的含量在制造商和批次之间差异很大。结论已开发出一种使用高效液相色谱(HPLC)的新方法,可对商用浓缩GT颗粒进行简单可靠的质量控制。通过多波长检测提高了灵敏度。 GT颗粒中所选标记物成分的含量在制造商和批次之间差异很大,因此有必要评估市场上浓缩GT颗粒的质量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号