Malaria is the second most prevalent disease in Pakistan resulting in ~30,000 annual deaths. In endemic countries like Pakistan precise and timely diagnosis of malaria is imperative to overcome the associated risks of fatal outcomes. Malarial parasite was screened in 128 malaria suspected patients and 150 healthy controls, by species-specific PCR, microscopy of blood smears, hemoanalyzer Sysmex XE-2100, and rapid test devices (First Response Malaria? and ICT Malaria Combo?). The microscopy detected MP in 126 samples (parasite load/μl 386–53712/μl); 71.094% were infected with Plasmodium vivax and 14.844% with P. falciparum while 14.062% had mixed P. vivax and P. falciparum infection. The mean parasite load for P. vivax and P. falciparum was 14496/μl and 24410/μl, respectively. The abnormal scattergrams of DIFF, WBC/ Baso, IMI channel, and RET-EXT on Sysmex XE-2100 supported 99.2% parasite detection, whereas only 93% of confirmed malaria cases were detected by both rapid tests. About 127 samples were positive by PCR. Since Sysmex XE-2100 automatically detected the presence of malarial parasite with high sensitivity, it can be a good option for presumptive diagnosis in endemic areas. Microscopy remains the gold standard to confirm MP in suspected patients. Rapid diagnostic tests have acceptable sensitivity and specificity.
机译:疟疾是巴基斯坦第二大流行疾病,每年造成约30,000人死亡。在像巴基斯坦这样的地方病国家,必须及时准确地诊断出疟疾,以克服致命后果的相关风险。通过物种特异性PCR,血液涂片显微镜检查,Sysmex XE-2100血液分析仪和快速测试设备(First Response Malaria?和ICT Malaria Combo?),对128名疟疾可疑患者和150名健康对照者进行了疟原虫筛查。显微术检测到126个样品中的MP(寄生物上样量/μl386–53712 /μl);间日疟原虫感染率为71.094%,恶性疟原虫感染率为14.844%,间日疟原虫和恶性疟原虫混合感染率为14.062%。间日疟原虫和恶性疟原虫的平均寄生虫负荷分别为14496 /μl和24410 /μl。 Sysmex XE-2100上DIFF,WBC / Baso,IMI通道和RET-EXT的异常散点图支持99.2%的寄生虫检测,而这两项快速检测仅发现了93%的确诊疟疾病例。 PCR阳性约127个。由于Sysmex XE-2100可以高灵敏度自动检测到疟原虫的存在,因此它可以作为流行病地区推测性诊断的好选择。显微镜检查仍是确认可疑患者MP的金标准。快速诊断测试具有可接受的敏感性和特异性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号