首页> 外文期刊>Brazilian Dental Journal >Bone damage induced by different cutting instruments: an in vitro study
【24h】

Bone damage induced by different cutting instruments: an in vitro study

机译:不同切割工具引起的骨损伤:一项体外研究

获取原文
           

摘要

The aim of this study was to compare the peripheral bone damage induced by different cutting systems. Four devices were tested: Er:YAG laser (2.94 mm), Piezosurgery, high-speed drill and low-speed drill. Forty-five bone sections, divided into 9 groups according to different parameters, were taken from pig mandibles within 1 h post mortem. Specimens were fixed in 10% buffered formalin, decalcified and cut in thin sections. Four different parameters were analyzed: cut precision, depth of incision, peripheral carbonization and presence of bone fragments. For statistical analysis, the Kruskal-Wallis test was applied to assess equality of sample medians among groups. All sections obtained with the Er:YAG laser showed poor peripheral carbonization. The edges of the incisions were always well-shaped and regular, no melting was observed. Piezosurgery specimens revealed superficial incisions without thermal damage but with irregular edges. The sections obtained by traditional drilling showed poor peripheral carbonization, especially if obtained at lower speed. There was statistically significant differences (p
机译:这项研究的目的是比较不同切割系统引起的周围骨损伤。测试了四种设备:Er:YAG激光(2.94毫米),压电外科手术,高速钻和低速钻。在死后1小时内从猪下颌骨中取下四十五块骨头,根据不同的参数分为9组。将样品固定在10%福尔马林缓冲液中,脱钙并切成薄片。分析了四个不同的参数:切割精度,切口深度,外周碳化和骨碎片的存在。为了进行统计分析,将Kruskal-Wallis检验用于评估各组样本中位数的相等性。用Er:YAG激光获得的所有切片均显示出较差的周边碳化。切口的边缘始终形状良好且规则,没有观察到熔化。压电外科手术标本显示浅表切口无热损伤,但边缘不规则。通过传统钻孔获得的断面显示出较差的周边碳化,特别是如果以较低的速度获得。有统计学差异(p

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号