首页> 外文期刊>Brazilian Dental Journal >Feldspar Ceramic Strength and The Reinforcing Effect by Adhesive Cementation Under Accelerated Aging
【24h】

Feldspar Ceramic Strength and The Reinforcing Effect by Adhesive Cementation Under Accelerated Aging

机译:长石在加速老化下的陶瓷强度和胶结水泥的增强作用

获取原文
           

摘要

This study evaluated the effect of the accelerated artificial aging (AAA) on feldspar ceramic strength and the reinforcing effect promoted by adhesive cementation with resin luting agent. One hundred twenty feldspar ceramic disks were obtained. Sixty disks were acid-etched, silanized, and coated with an experimental resin luting agent simulating the adhesive luting procedures. Four groups were created (n=30): uncoated ceramic (control group), uncoated ceramic submitted to AAA, ceramic coated with resin luting agent, and coated ceramic submitted to AAA. Biaxial flexural testing with ball-on-ring setup was carried out. Biaxial flexural strength (s bf , MPa), characteristic strength (s 0 , MPa), and Weibull modulus ( m ) were calculated for axial positions z=0 (ceramic surface) and z=?t 2 (luting agent surface). Data of s bf at positions z=0 and z=-t 2 were separately submitted to statistical analyses (a=0.05). The uncoated ceramic submitted to AAA had no significant difference in s bf and s 0 compared with the control group. Resin coating of the ceramic increased s bf and s 0 at z=0. The AAA increased the s bf and s 0 for the resin-coated ceramic specimens at z=0 and also the s 0 at axial position z=-t 2 . The structural reliability at z=0 and z=-t 2 was not influenced by the variables tested. In conclusion, resin coating improved the mechanical strength of the feldspar ceramic. The AAA procedure was not effective in aging the uncoated or resin-coated feldspar ceramic specimens.
机译:本研究评估了加速人工时效(AAA)对长石陶瓷强度的影响以及通过树脂浸润剂进行胶结胶凝促进的增强效果。获得了一百二十个长石陶瓷盘。六十个圆盘经过酸蚀刻,硅烷化处理,并涂有模拟粘合剂上胶程序的实验性树脂上胶剂。创建了四组(n = 30):未涂覆的陶瓷(对照组),未涂覆到AAA的陶瓷,涂覆有树脂浸润剂的陶瓷和涂覆到AAA的涂覆陶瓷。进行了带球环设置的双轴弯曲测试。对于轴向位置z = 0(陶瓷表面)和z =Δt2(稀释剂表面),计算了双轴弯曲强度(s bf,MPa),特征强度(s 0,MPa)和威布尔模量(m)。将z = 0和z = -t 2位置的s bf数据分别提交统计分析(a = 0.05)。与对照组相比,接受AAA处理的未涂层陶瓷的s bf和s 0没有显着差异。在z = 0时,陶瓷的树脂涂层增加了s bf和s 0。 AAA增加了在z = 0处的树脂涂层陶瓷试样的s bf和s 0,在轴向位置z = -t 2处的s 0。 z = 0和z = -t 2时的结构可靠性不受测试变量的影响。总之,树脂涂层改善了长石陶瓷的机械强度。 AAA程序无法有效地老化未涂层或树脂涂层的长石陶瓷样品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号