首页> 外文期刊>Brazilian Dental Journal >Irradiance and Radiant Exposures Delivered by LED Light-Curing Units Used by a Left and Right-Handed Operator
【24h】

Irradiance and Radiant Exposures Delivered by LED Light-Curing Units Used by a Left and Right-Handed Operator

机译:左右手操作员使用的LED光固化装置提供的辐照度和辐射度

获取原文
       

摘要

The combination of the restoration location, the hand preference of the operator using the light-curing unit (LCU), and the design of the LCU all can have an impact on the amount of the light delivered to the restoration. To evaluate the effect of left-handed or right-handed users, the position of the operator (dentist or assistant), and the LCU design on the irradiance, radiant exposure and emission spectrum delivered to the same posterior tooth. Two light emitting diode (LED) LCUs were tested: an angulated monowave LCU Radii-Cal (SDI, Victoria, Australia) and a straight aligned multi-peak LCU Valo Cordless (Ultradent, South Jordan, UT, USA). The irradiance values (mW/cm 2 ), radiant exposure (J/cm 2 ) and emission spectrum were measured using a sensor in maxillary left second molar tooth. The irradiance and radiant exposure were analyzed using three-way ANOVA followed by Tukey test (a=0.05). The emission spectra (nm) were analyzed descriptively. The interaction between LCU design, operator position, and hand preference significantly influenced the irradiance and radiant exposure (P0.001). In all cases, Valo delivered significantly higher irradiance than Radii-Cal. The handedness and the operator position affected the irradiance and radiant exposure delivered from Valo. Operator position and access affect the irradiance and radiant exposure delivered to the maxillary left second molar. The irradiance and radiant exposure can be greater when a right-hand operator is positioned on the right side of the chair and a left-hand operator is positioned on the left side of the chair. This may result in better resin composite polymerization.
机译:修复位置,操作人员使用光固化单元(LCU)的手偏爱以及LCU的设计都可能对传递到修复体的光量产生影响。为了评估惯用左手或惯用右手的用户,操作员(牙医或助手)的位置以及LCU设计对传递到同一颗后牙的辐照度,辐射暴露和发射光谱的影响。测试了两个发光二极管(LED)LCU:成角度的单波LCU Radii-Cal(SDI,澳大利亚维多利亚)和笔直排列的多峰LCU Valo无绳(Ultradent,南约旦,美国犹他州)。使用传感器测量左上颌第二磨牙中的辐照度值(mW / cm 2),辐射暴露(J / cm 2)和发射光谱。使用三向方差分析,然后进行Tukey测试(a = 0.05)分析辐照度和辐射暴露。描述性地分析了发射光谱(nm)。 LCU设计,操作员位置和手偏爱之间的相互作用显着影响了辐照度和辐射暴露(P <0.001)。在所有情况下,Valo的辐照度均比Radii-Cal高得多。惯用的手感和操作员的位置影响了Valo提供的辐照度和辐射暴露。操作者的位置和进入方式会影响照射到上颌左第二磨牙的辐照度和辐射暴露。当右手操作者位于椅子的右侧而左手操作者位于椅子的左侧时,辐照度和辐射暴露会更大。这可以导致更好的树脂复合聚合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号