首页> 外文期刊>British Journal of Medicine and Medical Research >Performance of First Response? and CareStart? Malaria Rapid Diagnostic Tests for the Detection of Plasmodium falciparum in a Tertiary Hospital in Ghana
【24h】

Performance of First Response? and CareStart? Malaria Rapid Diagnostic Tests for the Detection of Plasmodium falciparum in a Tertiary Hospital in Ghana

机译:执行第一反应?和CareStart?加纳一家三级医院的疟疾快速诊断测试,用于检测恶性疟原虫

获取原文
           

摘要

Background: Malaria poses a major public health problem in sub-Saharan Africa. In Ghana, millions of people are potentially at risk of Plasmodium falciparum infections annually. The current study evaluated the performance of two Histidine rich protein 2 (HRP-2) rapid diagnostic tests (First Response? and CareStart?) using giemsa stained microscopy (microscopy) as the gold standard. This cross-sectional study which took place at the Komfo Anokye Teaching Hospital (KATH) in Kumasi from October 2014 to March, 2015 was done to monitor the performance of RDTs that are used regularly in Ghana. Methodology: A total of 400 children (239 males, 161 females; age range 1-17 years) with fever or history suggestive of malaria were included in the study. First Response? and CareStart? diagnostic accuracy results were compared with that of microscopy. The strength of agreements (kappa) between the microscopy and the two RDTs were also calculated. Results: Of the 400 blood films that were examined using microscopy, Plasmodium parasites were detected in 33 (8.3%) of them. First Response? showed positive results in 65 (16.3%) and CareStart? showed positive results in 68 (17.0%). The sensitivities of both First Response? and CareStart? when compared with microscopy were 97.0% (95% CI: 84.2-99.9) and 97.0% (95% CI: 84.2-99.9) respectively. The specificities were First Response? 91.0% (95% CI: 87.6-93.7) and CareStart? 90.2% (95% CI: 86.7-93.0). The strength of agreement (kappa) between microscopy and First Response? and CareStart? with 95% confidence interval was good for the First Response? (giemsa stain microscopy vs First Response?: 0.61) and moderate for CareStart? (giemsa stain microscopy vs CareStart?: 0.59). Conclusion: The diagnostic accuracy of the First Response? and CareStart? RDTs to detect malaria was good with no significant differences between the two rapid test kits when compared with microscopy. The RDTs are a suitable alternative to microscopy to test for malaria in rural areas.
机译:背景:疟疾在撒哈拉以南非洲构成了主要的公共卫生问题。在加纳,每年都有数百万人面临恶性疟原虫感染的风险。当前的研究使用吉姆萨染色显微镜(显微镜)作为金标准,评估了两种富含组氨酸的蛋白质2(HRP-2)快速诊断测试(“第一反应”和“护理开始”)的性能。这项横断面研究于2014年10月至2015年3月在库马西的Komfo Anokye教学医院(KATH)进行,旨在监测加纳定期使用的RDT的性能。方法:研究共包括400名发烧或有疟疾史的儿童(男性239人,女性161人;年龄1-17岁)。第一反应?和CareStart?诊断准确性结果与显微镜检查结果进行了比较。还计算了显微镜和两个RDT之间的一致强度(kappa)。结果:在用显微镜检查的400幅血膜中,其中33例(8.3%)检出了疟原虫。第一反应?在65(16.3%)和CareStart中显示阳性结果?在68(17.0%)中显示阳性结果。两种反应的敏感性?和CareStart?与显微镜相比,分别为97.0%(95%CI:84.2-99.9)和97.0%(95%CI:84.2-99.9)。具体是“第一反应”? 91.0%(95%CI:87.6-93.7)和CareStart? 90.2%(95%CI:86.7-93.0)。显微镜检查和“第一反应”之间的一致性(kappa)强度?和CareStart?置信区间为95%的人群对于“第一反应”是否有效? (giemsa染色显微镜与首次反应?:0.61)和中等程度的CareStart? (giemsa染色显微镜与CareStart?:0.59)。结论:首次反应的诊断准确性?和CareStart?与显微镜相比,用于检测疟疾的RDT效果很好,两种快速检测试剂盒之间没有显着差异。 RDT是显微镜检查农村地区疟疾的合适替代方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号