首页> 外文期刊>Brazilian Journal of Microbiology >Assessment of the efficiency of SimPlate™ total plate count color indicator (TPC CI) to quantify mesophilic aerobic microorganisms in pasteurized milk
【24h】

Assessment of the efficiency of SimPlate™ total plate count color indicator (TPC CI) to quantify mesophilic aerobic microorganisms in pasteurized milk

机译:评估SimPlate™总板数显色指示剂(TPC CI)量化巴氏灭菌牛奶中嗜温好氧微生物的效率

获取原文
           

摘要

The SimPlate™ TPC CI system is a rapid method to count mesophilic aerobic microorganisms (MAM) in foods, based on the use of resazurine to indicate bacterial growth. Its efficiency in pasteurized milk was evaluated using 142 pasteurized milk samples (38 type A, 43 type B and 61 type C) collected in Londrina, PR. The standard plating method, using Plate Count Agar (PCA) was used for comparison. The plates of both systems were incubated at 35oC and read after 24h and 48h. The occurrence of false-positive and false-negative wells and the predominant microorganisms in them were also evaluated. The results were compared by simple correlation and mean variance analyses. The correlation (r) and mean variance values were 0.6811 and 0.7583 for the results obtained after 24h, respectively, and 0.9126 and 0.0842 for the results obtained after 48h, respectively. These results indicate that the performance of the system increases when the plates are incubated for 48h. When the three types of milk were evaluated separately, these values were 0.9285 and 0.0817 for type A milk, 0.9231 and 0.0466 for type B milk and 0.7209 and 0.1082 for type C milk. These results indicate that the better the quality of the milk the better the performance of SimPlate™ TPC CI. False-negative wells, found more frequently in samples with high MAM counts, were caused by Gram positive microorganisms, poorly detected by the SimPlate™ TPC CI system because they grew slowly and had low reduction capacity. The results indicated a higher efficiency of the SimPlate™ TPC CI system in the reading at 48h.
机译:SimPlate™TPC CI系统是一种快速的方法,可基于刃天青指示细菌的生长,对食品中的嗜温性好氧微生物(MAM)进行计数。使用在宾夕法尼亚州隆德里纳市收集的142个巴氏消毒奶样品(38种A型,43种B型和61种C型)对巴氏杀菌奶的效率进行了评估。使用平板计数琼脂(PCA)的标准电镀方法进行比较。两种系统的平板均在35oC下孵育,并在24h和48h后读取。还评估了假阳性和假阴性孔的发生以及其中的主要微生物。通过简单相关和均值方差分析比较结果。 24小时后获得的结果的相关性(r)和平均方差值为0.6811和0.7583,48小时后获得的结果的相关性(r)和平均方差分别为0.9126和0.0842。这些结果表明,将板孵育48小时后,系统的性能会提高。当分别评估这三种类型的牛奶时,A型牛奶的数值分别为0.9285和0.0817,B型牛奶的数值为0.9231和0.0466,C型牛奶的数值为0.7209和0.1082。这些结果表明,牛奶的质量越好,SimPlate™TPC CI的性能就越好。在高MAM计数的样品中发现的假阴性孔是由革兰氏阳性微生物引起的,由于它们生长缓慢且还原能力低,因此在SimPlate™TPC CI系统中很难检测到。结果表明,在48h的读数中,SimPlate™TPC CI系统具有更高的效率。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号