Renal replacement therapy (RRT) with regional citrate anticoagulation (RCA) is an important therapeutic approach for refractory hypercalcemia complicated with renal failure. However, RCA has the potential to induce arrhythmia caused by rapid calcium loss. We report a case of arrhythmia associated with rapid calcium loss during RCA-RRT. A 51-year-old man with hypercalcemia, primary hyperparathyroidism, and acute kidney injury was treated by predilutional-RCA-hemofiltration at a rate of 4.3?L/h. The effect of lowering serum calcium was unsatisfactory despite reducing calcium substitution gradually from 5.3 to 2.2?mmol/h in the first 8-h session of RCA-hemofiltration. New-onset sinus tachycardia with a prolonged QT interval occurred when calcium substitution was infused at rate of 1.1?mmol/h after 15?min of starting the second RCA-hemofiltration session (estimated net calcium loss was 7.54?mmol/h). When the calcium substitution was increased to usual rate of 5.6?mmol/h, the arrhythmia disappeared after 2?min. Arrhythmia did not recur when the calcium substitution rate was 2.2?mmol/h during the third session (estimated net calcium loss was 6.44?mmol/L). After the third RCA-hemofiltration session, the patient underwent parathyroidectomy and serum calcium returned to normal. This case indicated that rapid calcium loss may cause arrhythmia in RCA-hemofiltration, and the rate of net calcium loss should be limited below a threshold value to prevent similar adverse effect during RCA-RRT.
机译:肾替代疗法(RRT)和局部柠檬酸盐抗凝(RCA)是治疗难治性高钙血症并发肾衰竭的重要治疗方法。但是,RCA可能会引起钙快速流失引起的心律不齐。我们报告了在RCA-RRT期间快速钙丢失相关的心律不齐的情况。一名51岁高钙血症,原发性甲状旁腺功能亢进症和急性肾损伤的男子接受了稀释前RCA血液滤过术治疗,速度为4.3?L / h。尽管在RCA血液滤过的第一个8小时内将钙的替代量从5.3逐渐降低到2.2?mmol / h,但降低血清钙的效果仍不能令人满意。在第二次RCA血液滤过开始15分钟后,以1.1?mmol / h的速度注入钙替代物时,发生了QT间隔延长的新发窦性心动过速(估计净钙流失为7.54?mmol / h)。当钙替代增加到正常速率5.6?mmol / h时,心律失常在2?min后消失。在第三阶段,当钙替代率为2.2?mmol / h时,心律失常没有复发(估计净钙损失为6.44?mmol / L)。在第三次RCA血液滤过之后,患者进行了甲状旁腺切除术,血清钙恢复正常。这种情况表明钙快速流失可能会导致RCA血液滤过的心律失常,净钙流失率应限制在阈值以下,以防止RCA-RRT期间出现类似的不良反应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号