...
首页> 外文期刊>Brazilian Oral Research >Evaluation of surface characteristics of Ti-6Al-4V and Tilite alloys used for implant abutments
【24h】

Evaluation of surface characteristics of Ti-6Al-4V and Tilite alloys used for implant abutments

机译:评估用于种植体基台的Ti-6Al-4V和Tilite合金的表面特性

获取原文
           

摘要

The aim of this study was to evaluate surface free energy (SFE), surface roughness (SR) and surface hardness (SH) of two commercially available materials for fabricating dental implant abutments. In addition, the specimens were investigated by scanning electron microscopy (SEM) to determine the surface morphology. Twenty five discs (5 x 2 mm) of Ti-6Al-4V and Tilite (Ni-Cr-Ti) alloys were used in this study. Surface free energy was determined by the contact angle formed between a drop of distilled, deionized water and the surface of the specimen of each material. The surface roughness was measured with a mechanical profilometer and the surface hardness was evaluated by means of the Vickers hardness micro indentation test. SFE, SR and SH data were analyzed using one-way ANOVA (p < 0.05). Statistical differences (p < 0.05) were found between Ti-6Al-4V (36.2 erg.cm-2; 0.2 μm) and Tilite (30.9 erg.cm-2; 0.16 μm) for SFE and SR. However, the differences between the surface hardness values of Ti-6Al-4V (325.0 kg/mm2) and Tilite (324.3 kg/mm2) were not statistically significant (p > 0.05). Evaluations by SEM revealed different surface morphology. Within the limits of this study, it can be concluded that the Ti-6Al-4V and Tilite alloys showed differences in surface properties, except for surface hardness, suggesting that both alloys may be considered appropriate for producing abutments. Further studies are, however, necessary to elucidate the biological responses to implant abutments made with these alloys.
机译:这项研究的目的是评估两种市场上可买到的用于制造牙种植体基台的材料的表面自由能(SFE),表面粗糙度(SR)和表面硬度(SH)。另外,通过扫描电子显微镜(SEM)研究样品以确定表面形态。在这项研究中使用了25个Ti-6Al-4V和Tilite(Ni-Cr-Ti)合金圆盘(5 x 2 mm)。表面自由能由一滴蒸馏去离子水与每种材料的试样表面之间形成的接触角确定。用机械轮廓仪测量表面粗糙度,并通过维氏硬度微压痕试验评价表面硬度。使用单向方差分析分析SFE,SR和SH数据(p <0.05)。在SFE和SR的Ti-6Al-4V(36.2 erg.cm-2; 0.2μm)和Tilite(30.9 erg.cm-2; 0.16μm)之间发现统计学差异(p <0.05)。但是,Ti-6Al-4V(325.0 kg / mm2)和Tilite(324.3 kg / mm2)的表面硬度值之间的差异无统计学意义(p> 0.05)。 SEM评估显示出不同的表面形态。在本研究的范围内,可以得出结论,Ti-6Al-4V和Tilite合金除表面硬度外,表面性能均存在差异,这表明这两种合金均被认为适合于制造基台。但是,需要进一步的研究来阐明对这些合金制成的种植体基台的生物学反应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号