Estimates of adherence and error analysis of physical activity data collected via accelerometry in a large study of free-living adults

机译:在一项大型的自由成年成年人研究中,通过加速度计收集的身体活动数据的依从性和错误分析估计

获取原文
           

摘要

Background Activity monitors (AM) are small, electronic devices used to quantify the amount and intensity of physical activity (PA). Unfortunately, it has been demonstrated that data loss that occurs when AMs are not worn by subjects (removals during sleeping and waking hours) tend to result in biased estimates of PA and total energy expenditure (TEE). No study has reported the degree of data loss in a large study of adults, and/or the degree to which the estimates of PA and TEE are affected. Also, no study in adults has proposed a methodology to minimize the effects of AM removals. Methods Adherence estimates were generated from a pool of 524 women and men that wore AMs for 13 – 15 consecutive days. To simulate the effect of data loss due to AM removal, a reference dataset was first compiled from a subset consisting of 35 highly adherent subjects (24 HR; minimum of 20 hrs/day for seven consecutive days). AM removals were then simulated during sleep and between one and ten waking hours using this 24 HR dataset. Differences in the mean values for PA and TEE between the 24 HR reference dataset and the different simulations were compared using paired t-tests and/or coefficients of variation. Results The estimated average adherence of the pool of 524 subjects was 15.8 ± 3.4 hrs/day for approximately 11.7 ± 2.0 days. Simulated data loss due to AM removals during sleeping hours in the 24 HR database (n = 35), resulted in biased estimates of PA (p Conclusion Although estimated adherence was good, measurements of PA can be improved by relatively simple imputation of missing AM data.
机译:背景活动监视器(AM)是小型电子设备,用于量化身体活动(PA)的数量和强度。不幸的是,已证明当受试者未佩戴AM时发生的数据丢失(在睡眠和清醒时间移除)会导致PA和总能量消耗(TEE)的估计偏差。尚无研究报道大型成年人研究中的数据丢失程度,和/或PA和TEE估计值受到影响的程度。而且,没有针对成年人的研究提出了将AM去除的影响降至最低的方法。方法从524名连续13到15天穿AM的男女中得出依从性评估。为了模拟由于去除AM而造成的数据丢失的影响,首先从35个高度依从的受试者(24 HR;连续7天每天至少20个小时/天)组成的子集中编译了一个参考数据集。然后使用这24个HR数据集模拟AM在睡眠期间和1至10个清醒小时之间的去除量。使用配对的t检验和/或变异系数比较了24个HR参考数据集和不同模拟之间的PA和TEE平均值差异。结果524名受试者的平均估计依从性为15.8±3.4小时/天,持续约11.7±2.0天。在24 HR数据库中(n = 35),由于在睡眠时间因AM去除而造成的模拟数据丢失,导致对PA的估计存在偏差(p结论尽管依从性良好,但可以通过相对简单地估算缺失的AM数据来改善PA的测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号