Introduction In many practical aspects of ophthalmology, it is necessary to assess the severity degree of glaucoma in cases where, for various reasons, it is impossible to perform a visual field test - static perimetry. These are cases in which the visual field test result is not reliable, e.g. advanced AMD (Age-related Macular Degeneration). In these cases, there is a need to determine the severity of glaucoma, mainly on the basis of optic nerve head (ONH) and retinal nerve fibre layer (RNFL) structure. OCT is one of the diagnostic methods capable of analysing changes in both, ONH and RNFL in glaucoma. Material and method OCT images of the eye fundus of 55 patients (110 eyes) were obtained from the SOCT Copernicus (Optopol Tech. SA, Zawiercie, Poland). The authors proposed a new method for automatic determination of the RNFL (retinal nerve fibre layer) and other parameters using: mathematical morphology and profiled segmentation based on morphometric information of the eye fundus. A quantitative ratio of the quality of the optic disk and RNFL – BGA (biomorphological glaucoma advancement) was also proposed. The obtained results were compared with the results obtained from a static perimeter. Results Correlations between the known parameters of the optic disk as well as those suggested by the authors and the results obtained from static perimetry were calculated. The result of correlation with the static perimetry was 0.78 for the existing methods of image analysis and 0.86 for the proposed method. Practical usefulness of the proposed ratio BGA and the impact of the three most important features on the result were assessed. The following results of correlation for the three proposed classes were obtained: cup/disk diameter 0.84, disk diameter 0.97 and the RNFL 1.0. Thus, analysis of the supposed visual field result in the case of glaucoma is possible based only on OCT images of the eye fundus. Conclusions The calculations and analyses performed with the proposed algorithm and BGA ratio confirm that it is possible to calculate supposed mean defect (MD) of the visual field test based on OCT images of the eye fundus.
机译:引言在眼科的许多实际方面,由于各种原因无法进行视野测试-静态视野检查,有必要评估青光眼的严重程度。在这些情况下,视野测试结果不可靠,例如先进的AMD(与年龄有关的黄斑变性)。在这些情况下,需要确定青光眼的严重程度,主要根据视神经头(ONH)和视网膜神经纤维层(RNFL)结构来确定。 OCT是能够分析青光眼ONH和RNFL两者变化的诊断方法之一。材料和方法从SOCT哥白尼公司(Optopol Tech。SA,Zawiercie,Poland)获得了55名患者(110眼)眼底的OCT图像。作者提出了一种自动确定RNFL(视网膜神经纤维层)和其他参数的新方法,该方法使用:数学形态学和基于眼底形态信息的轮廓分割法。还提出了视盘质量与RNFL – BGA(生物形态性青光眼进展)的定量比。将获得的结果与从静态周边获得的结果进行比较。结果计算了视盘的已知参数之间以及作者建议的参数之间的相关性,以及从静态视野测量获得的结果之间的相关性。现有的图像分析方法与静态视野测量的相关结果为0.78,建议的方法为0.86。评估了建议的比率BGA的实际实用性以及三个最重要特征对结果的影响。对于三个提议的类别,获得了以下相关结果:杯/盘直径0.84,盘直径0.97和RNFL 1.0。因此,仅基于眼底的OCT图像就可以分析青光眼情况下的假想视野结果。结论使用所提出的算法和BGA比率进行的计算和分析证实,可以根据眼底的OCT图像计算视野测试的假设平均缺陷(MD)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号