Three dimensional Swept source OCT accurately measures optic disc volume in primary open angle glaucoma and correlates with severity of visual field loss

机译:三维扫频OCT技术可准确测量原发性开角型青光眼的视盘容量,并与视野丧失的严重程度相关

获取原文
           

摘要

?Purpose?To measure optic nerve cup volume (CV) in primary open angle glaucoma (POAG) using 3-dimensional [3D] swept-source optical coherence tomography (SS-OCT) and correlate with severity of visual field loss. ?Methods?In this prospective, observational case series, SS-OCT scans of the optic nerve head (ONH) (12X9-mm area; 100000 B-scans; interval 100μ) were obtained in 64 POAG eyes. Bruch’s membrane opening (BMO) and anterior lamina cribrosa boundary were automatically delineated. The point with maximum lamina cribrosa (LC) depth and pre-laminar neural (PLT) thickness were averaged. RPE edge points, which are detected radially from the disc center were outlined with automated software. By default, the "referring surface” was set optionally 120μm above the RPE edge. Cup volume of the area surrounded by the reference surface and ILM line was calculated. 30 - 2 HVF analysis along with SS - OCT optic nerve analysis were done in all patients. Reliability of HVF in all the subjects was good (false positive 20%, false negative 20% and fixation losses 33%). All investigations were done on the same day or within a week of each other. ?Results?Mean age of the cohort was 63.5 years (median - 64 yrs). There were 18 females and 14 males included in the study. There were 28 African American and 4 Caucasians. Mean IOP was 14.21 (SD - 3.07) mm Hg, with a range of 9 - 21 mm Hg. On HVF analysis, average mean deviation (MD) was - 4.12 and average pattern standard deviation (PSD) was 4.26. Mean cup volume (CV) in our cohort was 0.45 cu mm and mean cup to disc ratio (CDR) was 0.75. The value of R (Pearson’s correlation coefficient) between CV and MD was -0.63 and that between CV and PSD was 0.64. However, there was a weak correlation between CV and CDR (R - 0.28). ?Conclusions?SS - OCT objectively and accurately measured cup volume in POAG and correlated well with the visual field loss. This may be a useful tool in the longitudinal monitoring of primary open angle glaucoma. ?View OriginalDownload SlideView OriginalDownload Slide ?.
机译:目的:使用3D [3D]扫描源光学相干断层扫描(SS-OCT)测量原发性开角型青光眼(POAG)的视神经杯体积(CV),并将其与视野丧失的严重程度相关联。方法:在此前瞻性观察病例系列中,对64只POAG眼睛进行了SS-OCT扫描,对视神经头(ONH)进行了扫描(面积为12X9毫米; 100000次B扫描;间隔为100μ)。会自动绘制Bruch的膜开口(BMO)和前筛板的边界。将具有最大椎板(LC)深度和椎板前神经(PLT)厚度的点平均。从光盘中心径向检测到的RPE边缘点已通过自动化软件进行了概述。默认情况下,“参考面”设置为可选,位于RPE边缘上方120μm处,计算参考面和ILM线所包围区域的杯体积,在所有位置均进行30-2 HVF分析以及SS-OCT视神经分析所有患者的HVF可靠性均良好(假阳性<20%,假阴性<20%,固定损失<33%),所有检查均在同一天或一周内进行。该队列的平均年龄为63.5岁(中位数-64岁),包括18位女性和14位男性,其中28位非裔美国人和4位白种人,平均IOP为14.21(SD-3.07)mm Hg,范围为9-21 mm Hg。在HVF分析中,平均平均偏差(MD)为-4.12,平均图案标准偏差(PSD)为4.26。我们队列中的平均杯体积(CV)为0.45立方毫米,并且平均杯与盘比值(CDR)为0.75,CV和MD之间的R(皮尔森相关系数)为-0.63,CV和P之间的R(皮尔逊相关系数)为-0.63 SD为0.64。但是,CV和CDR之间的相关性较弱(R-0.28)。结论:SS-OCT客观准确地测量了POAG中的杯体积,并与视野损失密切相关。这在纵向监测原发性开角型青光眼中可能是有用的工具。查看原始下载幻灯片查看原始下载幻灯片。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号